ボイラー Ariston microGENUS II 31 MFFIのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Ariston microGENUS II 31 MFFI 8 ページ。
C
P
ONTROL
ANEL
2. OPERATING INSTRUCTIONS
K
E
C
L
:
EGEND
A - On/Off Switch
B - Domestic Hot Water Temperature Adjustment
C - Central Heating Temperature Adjustment
D - Reset Button
E - Comfort Mode Selector
F - Hot Water (Summer Mode LED - Green)
G - Ignition/Overheat Lockout LED (Red)
H - Central Heating (Winter Mode) LED (Green)
I - Digital Display (Fault Code/Water Temperature)
J - Time Clock
K-Central Heating System Pressure Gauge
In the United Kingdom installation, start-up, adjustments and maintenance must be
performed by a CORGI Registered Installer in accordance with the installation
standards currently in effect, as well as with any and all local health and safety
standards i.e.. CORGI.
In the Republic of Ireland the installation and initial start up of the appliance must
be carried out by a Competent Person in accordance with the current edition of
I.S.813 "Domestic Gas Installations", the current Building Regulations, reference
should also be made to the current ETCI rules for electrical installation.
To get the most out of your boiler, we have provided you with some useful advice on
proper use and maintenance:
- Periodically check the system pressure using the pressure gauge "D", make sure that
the pressure is at 1.5 bar when the system is off and cool. If the pressure is below the
minimum recommended value (1 bar). To refill the system, open the two black handles
connected to the silver flexible hose, once the pressure gauge "K" reads 1.5 bar close
the valves again.
N
: D
OTE
O NOT UNDER ANY CIRCUMSTANCES USE THE APPLIANCE WITH THE PRESSURE GAUGE
.
READING ZERO
- The outer panels of the unit's case must only be cleaned with a damp cloth. Do not use
abrasive cleaners. The control panel can be wiped with either a damp or dry cloth.
Spray polishes must not be used on the control panel surface or knobs. Care must be
taken to prevent any liquid from entering the appliance.
- If the water is very hard, it is recommended that a water softener be added to the
system so as to reduce the formation of limescale in the boiler exchangers. This will
I
I I
C
AUTION
H
S
ELPFUL
UGGESTIONS
P
RACTICAL TIPS
J
K
3