- ページ 4

ボイラー Ariston SB 125 IndirectのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Ariston SB 125 Indirect 20 ページ。 Type c

Ariston SB 125 Indirect 取付説明書
1.2
O
V
VERALL
IEW
L
:
EGEND
1.
Flue connector
2.
Fan
3.
Combustion chamber hood
4.
Main heat exchanger
5.
Safety thermostat
6.
Combustion chamber
7.
Combustion chamber insulation panel
8.
Detection electrode
9.
Ignition electrodes
10.
Burner
11.
Regulation thermostat
12.
Frost thermostat
13.
Pump pressure switch
14.
Safety valve (3 bar)
15.
Automatic By-pass
16.
Gas valve
17.
Spark generator
18.
Boiler drain valve
19.
Circulation pump with automatic air release valve
20.
Expansion vessel
21.
Air pressure take-off point
22.
Air pressure switch
23.
Combustion analysis points
2.

INSTALLATION

2.1
R
S
EFERENCE
TANDARDS
Supplied By www.heating spares.co Tel. 0161 620 6677
The technical information and instructions provided herein below are intended for the
installer so that the unit may be installed correctly and safely.
The installation and initial start up of the boiler must be by a CORGI Registered
Installer in compliance with the installation standards currently in effect, as well as
with any and all local health and safety standards i.e. CORGI .
This appliance must be installed by a competent installer in accordance with
current Gas Safety (installation & use) Regulations.
The installation of this appliance must be in accordance with the relevant
requirements of the current Gas Safety (installation & use) Regulations, the Local
Building Regulations, the current I.E.E. Wiring Regulations, the byelaws of the local
water authority, and in Scotland, in accordance with the Building Standards
(Scotland) Regulation and Health and Safety document No. 635 "Electricity at work
regulations 1989".
Installation should also comply with the following British Standard Codes of Practice:
BS 7593:1992
Treatment of water in domestic hot water central
heating systems
BS 5546:1990
Installation of hot water supplies for domestic
purposes
BS 5440-1:1990 Flues
BS 5440-2:1989 Air supply
BS 5449:1990
Forced circulation hot water systems
BS 6789:1987
Installation of gas fired hot water boilers of rated
input not exceeding 60kW
BS 6891:1989
Installation of low pressure gas pipe up to 28mm
BS 7671:1992
IEE wiring regulations
BS 4814:1990
Specification for expansion vessels
BS 5482:1994
Installation of LPG
4
F
. 1.0
IG