THE APPLIANCE MUST BE EARTHED
The hob is designed to work with alternating current at the
supply voltage and frequency indicated on the rating plate
(situated under the hob or at the end of the instruction
booklet). Make sure that the local supply voltage
corresponds to the voltage indicated on the rating plate.
Connecting the supply cable to the mains electricity
supply
For models supplied without a plug, fit a standard plug,
suitable for the load indicated on the rating plate, onto the
cable and connect to a suitable socket. To connect directly
to the mains supply, a double-pole switch with a contact
separation of at least 3 mm suitable for the load and
complying with current standards and regulations, must
be fitted between the appliance and the mains supply outlet.
The yellow-green earth wire must not be interrupted by the
switch. The supply cable must be in such a position that no
part of it can reach a temperature of 50 °C above room
temperature. For installation above a built-under oven, the
hob and the oven must be connected separately to the
electricity supply both for safety reasons and for easy
removal of the oven if necessary. Do not use adapters or
shunts as they could cause heating or burning. Before
connecting to the power supply, make sure that:
BURNERS AND NOZZLES SPECIFICATIONS
Outer Wok Burner
Inner Wok Burner
Triple ring gas burner
Large Burner
Medium Burner
Small Burner
Total NHGC (only for CP 059 MD AUS)
Total NHGC (only for CP 859 MT AUS)
Oven size
width
depth
Height
Voltage end frequency:
Power supply Max:

ELECTRICAL CONNECTION

NATURAL
Injector
Diameter
2x1.25
0.80
1.75
1.29
1.10
0.80
mm. 590
mm. 385
mm. 357
litres 68
230-240V / 50Hz
2850 - 3105 W
10
• the limiter valve and the domestic system can withstand
the load from the appliance (see rating plate);
• the supply system is efficiently earthed according to
standards and laws in force;
• the socket or double-pole switch are easily accessible
when the appliance is installed.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked "E" or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked "L" or
coloured Red. Connect the Blue wire to the terminal marked
"N" or coloured Black. FAILURE TO OBSERVE THE
ACCIDENT-PREVENTION REGULATIONS RELIEVES THE
MANUFACTURER OF ALL LIABILITY.
Replacing the cable
Use a rubber cable of the type H05VV-F with a suitable
cross section 3 x 1.5 mm². The yellow-green earth wire
must be 2-3 cm longer than the other wires.
MJ/H
Gas
Injector
Pressure
Diameter
15.5
1.0
2x0.75
3.3
1.0
0.50
15.0
1.0
1.05
8.3
1.0
0.80
6.0
1.0
0.64
3.3
1.0
0.50
42.4
38.6
- Earth
- Neutral
- Live
PROPANE
MJ/H
Gas
Pressure
15.0
2.75
3.5
2.75
15.0
2.75
9.0
2.75
5.5
2.75
3.5
2.75
42.0
38.5
AUS