Ariston ASL75CXSNA 修理マニュアル

14. DRAIN MOTOR

The Drain Motor and Float Switch are located under the Drain Housing Cover (Fig. 14-1).
To open the Drain Housing Cover insert a flat blade screwdriver behind each clip and unhook each latch (Fig. 14-2).
The Float Switch is located on the left, and the Drain Motor is located on the right. The Base Plate can be removed to access the
float by releasing the two locking clips (Fig. 14-3) and pulling the complete Base Plate up from the reservoir.
TECH NOTE: If the reservoir is full of water the Float Switch will disengage the Heating Element.
REPAIR MANUAL
Fig. 14-1
ASL75CXS NA
Fig. 14-2
Fig. 14-3
Page: 13