
2. INSTALLATION RESPONSIBILITIES
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED
IN ACCORDANCE WITH AS/NZ 2918:2001 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED
TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE
WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM
DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION
OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE
SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE
CONSULTED IN THE FIRST INSTANCE.
Strict adherence to these instructions will meet these standards.
Any variation from these installation instructions or any doubt about them must be
checked against the requirements of the Standards.
Please leave this manual with the owner when installation is complete.
3. FLOOR PROTECTOR REQUIREMENTS
The heater should always be installed on top of its base due to high temperatures
sustained over long periods. The base must be anchored to both the floor protector and
the floor for seismic restraint. Anchor points are provided in the base or on the rear
legs.
PEDESTAL, DRAWER BASE & LEGS MODELS:
If the heater is to be placed on or within 500mm of a heat sensitive floor, an insulated
40mm
floor protector with a minimum thickness of
is required consisting of 20mm of
an approved insulation material i.e. 2 sheets of 10mm micorboard or superlux, 10mm
tile backing board and 10mm tiles or similar on the top surface. All joints on the upper
surface should be sealed to prevent spilt ash from contacting any heat-sensitive
material.
Bronte Top Outlet AG Installation
4