- ページ 3

薪ストーブ Firenzo CONTESSAのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Firenzo CONTESSA 9 ページ。 Freestanding clean air woodburner
Firenzo CONTESSA にも: マニュアル (10 ページ), インストレーション・マニュアル (8 ページ), 設置および操作マニュアル (17 ページ)

Firenzo CONTESSA ユーザーマニュアル

1.Specification

This appliance has been tested for intermittent burning
Model
Weight
Nominal heat output
Mean CO emission (at 13% O
Mean flue gas temperature
Flue gas mass flow
Maximum hearth temperature
Distances from combustibles
To rear
To sides

2. Note of references to the current UK regulations

In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other
specifications or regulations as they affect the installation of the stove.
It should be noted that the Building Regulations requirements may be met by adopting the relevant
recommendations given in British Standards BS 8303, BS EN 15287-1:2007 as an alternative means to achieve
an equivalent level of performance to that obtained following the guidance given in Approved Document J.
Please note that it is a legal requirement under England and Wales Building Regulations that the installation of
the stove is either carried out under Local Authority Building Control approval or is installed by a Competent
Person registered with a Government approved Competent Persons Scheme. HETAS Ltd operate such a
Scheme and a listing of their Registered Competent Persons can be found on their website at
This stove must not be installed into a chimney that serves any other heating appliance.

3. Safety information

All surfaces on the Lady Kitchener will get hot and cause burning if touched by bare hands. Firenzo
recommends using a fireguard.
The heat from the Lady Kitchener will effectively dry laundry and other wet articles; however such materials
including soft furnishings should be kept well clear of the heater to prevent accidental fires.
In case of chimney fire call 999, move materials away from stove and chimney if safe to do so, shut down
controls if safe to do so. Do not endanger any lives.

4. The chimney

An efficient, modern stove places great demands on the chimney, so have a chimney sweep check the condition
of your chimney.
This stove must not be installed into a chimney that serves any other heating appliance.
The aperture of the chimney must comply with national and local regulations specifically section 2 of Approved
Document J of the Building Regulations (ADJ). We recommend you consult your installer to ensure your
installation will be compliant.
An overly large chimney aperture will mean that too much energy will be required to heat the chimney sufficiently
to achieve an acceptable draught. If you have a brick chimney with a large aperture, we recommend that you
install an insulating chimney liner of the proper diameter.This will increase the draught, and improve the fuel
economy.
The height and positioning of the chimney must comply with the guidance given in Approved Document J of The
Building Regulations, particularly Sections 2.6 – 2.21 (pages 29-35).
CU-2013-05-14
Contessa
kg
kW
)
%
2
°C
g/s
°C
mm
mm
133
10.7
0.17
363
9.6
37
215
150
3
www.hetas.co.uk