AEQ PHOENIX AUDIOCODECS. APPLICATION NOTE 0-B
Connecting AEQ Phoenix Mobile units through Internet via
exclusive DSL or cable modem with DHCP router
(Adapted to Phoenix Mobile user interface)
The most convenient and reliable way to connect an IP codec to a remote one through
Internet is by means of a dedicated, exclusive Internet access (DSL, cable modem) as
described below. No other equipments (PC, etc) are connected to this same access.
The modem itself usually has an embedded DHCP server that automatically assigns
valid IP address / mask, gateway and DNS server to the IP system(s) connected to it.
This application note also describes the recommended procedure when AEQ SIP
Proxy is used, where both equipments involved in the communication are registered,
easing the task of finding the remote IP address when it is variable or unknown.
This document shows the specific steps to make this connection possible in the most
general way possible, although some verification procedures have been omitted in
order to ease the reading, and some particular situations may be easier to solve that
the presented one.
For a detailed explanation of every step, and for details on how to configure other
options that may be more convenient for other cases, the reading of the rest of
application notes, as well as chapter 4 of user's manual, is recommended.
1. CONNECTING AND CONFIGURING THE EQUIPMENT
The physical connection will be done through a LAN port.
Connect the network cable to the LAN port at the back of the AEQ Phoenix
Mobile. Connect the other end to the Ethernet port to the router LAN port.
Connect at least a microphone and a pair of headphones to the front audio XLR
connectors of the Phoenix Mobile
Connect the power supply cable to the AEQ Phoenix Mobile. If it is equipped
with a battery pack and mains power is not available, you can omit this step.
Press the ON button at the left side of AEQ Phoenix Mobile. Verify that the main
display is illuminated.
Verify, at the back of the unit, that the green LED at the right of the Ethernet
port starts blinking indicating that the IP connection is active.
Configuring the Ethernet port and assignation of Program channel:
TEL: (34) 91 686 13 00 - FAX: (34) 91 686 44 92 - E-mail: [email protected] - Web:
APLICACIONES ELECTRONICAS QUASAR S.A.
2
www.aeq.eu