- ページ 6
ドライヤー Whirlpool CGM2751TQ0のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Whirlpool CGM2751TQ0 36 ページ。 Commercial gas or electric dryer
Whirlpool CGM2751TQ0 にも: パーツリスト (10 ページ), パーツリスト (10 ページ)
!!!!iL;i_i:i:_!i:!i_ii,i:t;i!di
_:i_i:i!!_i:Fdiii_i:!_fi:i_ii!tiiii_ii:4i_
...(_i!iiiil ! i)iiT_i!'_!
'_
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong,
Do not use an adapter,
Do not use an extension
cord.
Failure to follow these instructions
can result in death,
fire, or electrical
shock,
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence of
local codes, with the National Electrical Code, ANSI/NEPA 70,
latest edition, or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA Intemationa!
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
[]
A 120-volt, 60-Hz, AC-only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended.
It is recommended
that a separate circuit
serving only this dryer be provided.
Recommended
Ground
Method
The dryer, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSl/NEPA 70, latest edition,
or Canadian ElectricaI Code, CSA C22.1, and a!l local codes and
ordinances.
GROUNDING
INSTRUCTIONS
For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of a malfunction or
breakdown, grounding wiii reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
>
:
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence
of local codes, with the National Electrical Code, ANSI/NEPA 70,
latest edition, or Canadian Electrical Code, CSA C22.1.
The National Electric Code requires a 4-wire supply connection
for homes built after 1996, dryer circuits involved in remodeling
after 1996, and all mobile home installations.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch
Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
[]
In U.S.: A four-wire or three-wire, single-phase,
120/240-volt,
60-Hz, AC-only electrical supply (or four-wire or three-wire,
120/208-volt,
if specified on the modeI/serial rating plate) is
required on a separate, 30-amp circuit, fused on both sides of
the line. A time-delay fuse or circuit breaker is recommended.
[]
In Canada: A four-wire only, single phase 115/230-volt, 60-Hz
electrical supply is required on a separate, 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended.