- ページ 12

ドライヤー Whirlpool CGM2793BQのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Whirlpool CGM2793BQ 48 ページ。 Commercial dryer gas or electric
Whirlpool CGM2793BQ にも: 取付説明書 (48 ページ)

Whirlpool CGM2793BQ 取付説明書
ELECTRIC
DRYER INSTALLATION
REQUIREMENTS
Direct
Wire
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
if connecting
by direct
wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
[]
Flexible armored cable or nonmetallic
sheathed copper
cable (with ground wire), covered with flexible metallic
conduit. All current-carrying
wires must be insulated.
[]
10-gauge solid copper wire (do not use aluminum).
[]
At least 5 ft. (1.52 m) long.
Electrical
Requirements
= Canada
only
!
Electrical
Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate
and in conformance
with the Canadian Electrical Code,
C22.1 - latest edition and all local codes. A copy of the
above codes standard may be obtained from: Canadian
Standards Association,
178 Rexdale Blvd., Toronto, ON
M9W 1R3 CANADA.
[] To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended.
Connect to an individual
branch circuit.
[] This dryer is equipped with a CSA International/_
Certified Power Cord intended to be plugged
/r,
kJ '_
into a standard 14-30R wall receptacle. The
_
II
II)
cord is 5 ft (1.52 m) in length. Be sure wall
\''
_-q ''J
receptacle is within reach of dryer's final
location.
4-Wire
Receptacle
(14-30R}
[]
Do not use an extension cord.
If you are using a replacement
power supply cord,
it is recommended
that you use Power Supply Cord
Replacement Part Number 9831317. For further information,
please reference the service numbers located in the
"Assistance or Service" section.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding
conductor and a grounding
plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
12