Explosion Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the
floor for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need
•
A location that allows for proper exhaust installation. See
"Venting Requirements."
•
A separate 30 amp circuit.
•
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
•
A sturdy floor to support the total dryer weight of 200 Ibs
(90.7 kg). The combined weight of a companion
appliance
should also be considered.
A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer. If slope is greater than 1 in. (2.5 cm), install
Extended Dryer Feet Kit, Part No. 279810. Clothes may not
tumble properly and automatic sensor cycles may not
operate correctly if dryer is not level.
•
For a garage installation, you will need to place the dryer at
least 18 in. (46 cm) above the floor. If using a pedestal, you
will need an additional 6 in. (15.24 cm).
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation
clearances
•
The location must be large enough to fully open the dryer
door.
•
Additional spacing should be considered for ease of
installation and servicing.
•
Additional clearances might be required for wall, door and
floor moldings.
•
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
•
Companion appliance spacing should also be considered.
Dryer Dimensions
*Most installations require a minimum 51/2in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
installation
spacing for custom
undercounter
installation
The dimensions
shown are for the minimum spacing allowed.
Custom undercounter
installation - Dryer only
0"
--
27"
--
0 _'
(0 cm) --'_(68.6
cm'_l
_(--
(0 cm)
Minimum
installation
spacing for recessed
or closet
installation,
with or without a pedestal
•
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
Closet installation - Dryer only
_'_
48 in. 2
{310 cm2) -
24 in. 2
(155 cm2)
I0"N- 31,J_" _1 0"1
(0cm) (80cm) (0crn)
#
!. Side view - closet or confined area
2. Closet door with vents
__t
3"
.(7.6 cm)
+
,(7,6 cm)
+