Gas Dryer

PRODUCT MODEL NUMBERS
LGR8620P
WGD5530S
LGR8648P
WGD5540S
WGD5100S
WGD5550S
WGD5200T
WGD5600S
WGD5300S
WGD5700S
WGD5500S
WGD5790S
WGD5520S
WGD5800S
Gas supply:
1/2" IPS pipe is recommended.
3/8" approved tubing is acceptable for lengths
under 20 ft (6.1 m) if local codes and gas supplier
permit.
Must include 1/8" NPT minimum plugged tapping
accessible for test gauge connection, immediately
upstream of the gas connection to the dryer.
Must include a shutoff valve:
An individual manual shutoff valve must be
installed within six (6) feet (1.8 m) of the dryer in
accordance with the National Fuel Gas Code, ANSI
Z223.1. The location should be easy to reach for
opening and closing.
The gas pipe that comes out through the rear of
your dryer has a 3/8" male pipe thread.
Electrical: 120-Volt, 60-Hz., AC-only, 15- or
20-amp fused electrical supply is required. (Time-
delay fuse or circuit breaker is recommended.) It is
recommended that a separate circuit serving only
this dryer be provided.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12" (30.5 cm) from the ground or
any object that may be in the path of the exhaust.
EXHAUST VENTING
Box hood style
4"
(10.2 cm)
4"
(10.2 cm)
Louvered style
Vent Length Chart
Number of
Type of
90° turns
vent
or elbows
0
Rigid metal
64 ft (20 m)
Flexible metal
36 ft (11 m)
1
Rigid metal
54 ft (16.5 m)
31 ft (9.4 m)
Flexible metal
2
Rigid metal
44 ft (13.4 m)
Flexible metal
27 ft (8.2 m)
3
Rigid metal
35 ft (10.7 m)
25 ft (7.6 m)
Flexible metal
4
Rigid metal
27 ft (8.2 m)
Flexible metal
23 ft (7 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
PRODUCT DIMENSIONS
WGD5800V
WGD5810S
WGD5820S
WGD5830S
A. Small Opening
WGD5840S
Side-Swing Door
WGD5850S
B. Large Opening
WGD5900S
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
RECESSED AREA AND CLOSET INSTALLATION
For closet installation
with a door, minimum
ventilation openings in
the top and bottom of
the door are required.
Louvered doors with
equivalent air openings
are acceptable.
4"
(10.2 cm)
2.5"
(6.4 cm)
Angled style
Box or
Angled
Louvered
hoods
hoods
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
29 ft (8.8 m)
17 ft (5.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
43³⁄₈"
(110cm)
*26"
(66cm)
(73.66cm)
43 ³⁄₈"
(110cm)
*27³⁄₄"
(70.5 cm)
(73.66cm)
*Most installations require a minimum 5-1/2" (14 cm) clearance
behind the dryer for the exhaust vent with elbow.
18"
(45.7 cm)
1"
29"
(2.5 cm)
(73.66 cm)
A
1. Select the route that will provide the straightest and most direct path outdoors. Plan
the installation to use the fewest number of elbows and turns. When using elbows or
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.
Avoid 90° turns.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent
lengths you can use.
3. Determine the number of elbows you will need.
NOTE: Do not use vent runs longer than specified in the Vent Length Chart.
The chart at left helps you determine your maximum vent length based on the number
of 90° turns or elbows you will need and the type of vent (rigid or flexible metal) and
hood that you will use.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
15¹⁄₄"
(38.74 cm) 43 ³⁄₈"
(110cm)
*27 ³⁄₄"
(70.5cm)
29"
A
22³⁄₄"
³⁄₈ "
(57.8 cm)
43
(110cm)
*27³⁄₄"
(70.5 cm)
29"
C
14" max.
48 in.
(35.6 cm)
(310 cm )
24 in.
(155 cm )
1"
1"
27³⁄₄"
5¹⁄₂"
(14 cm)
(2.5 cm)
(2.5 cm)
(70.5 cm)
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
22 ³⁄₄"
(57.8cm)
29"
(73.66cm)
B
13 ³⁄₄ "
(34.9cm)
29"
(73.66cm)
D
3"
(7.6 cm)
2
2
2
3"
2
(7.6 cm)
C