ドライヤー Whirlpool WGD95HEXのPDF 製品寸法をオンラインで閲覧またはダウンロードできます。Whirlpool WGD95HEX 1 ページ。 Whirlpool gas dryer dimensions
Whirlpool WGD95HEX にも: 寸法と設置 (2 ページ), 仕様 (1 ページ), 取扱説明書 (40 ページ)

Whirlpool WGD95HEX 製品寸法
PRODUCT MODEL NUMBERS
WGD94HEX, WGD95HEX,
WGD97HEX, WGDXXHEX
:
Gas supply
This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid
pipe is used it should be 1/2" IPS. When acceptable
to the gas supplier and local codes, 3/8" approved
tubing may be used for lengths under 20 ft (6.1 m).
For lengths over 20 ft (6.1 m), larger tubing should be
used. Pipe-joint compounds resistant to the action of
L.P. gas must be used. An individual manual shutoff
valve must be installed within 6 ft (1.8 m) of the dryer
in accordance with the National Fuel Gas Code ANSI
Z223.1.
Electrical
:
A 120-volt, 60 Hz, AC-only, 15 or 20 amp
fused electrical supply is required. A time-delay fuse or
circuit breaker and a separate circuit are recommended.
:
Water (Steam models only)
The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
Exhaust venting
:
Exhaust your dryer to the outside. 4"
(102 mm) diameter vent is required. Rigid or flexible metal
exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
A
B
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
The vent system chart provides venting requirments
that will help to achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.
Vent system chart
Number of
Type
Box/louvered
90° elbows
of vent
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Do not use vent runs longer than specified in vent
length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
C
Angled
hoods
hoods
64 ft. (20 m)
58 ft. (17.7 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)

Gas Dryer

OVERALL DIMENSIONS
Dryer dimensions
Front view:
27"
(686 mm)
38
"
1 /8
(968 mm)
"*
3 /4
(18 mm)
Back view:
5
/
"*
3
4
(146 mm)
3
/
"*
4
14
/
"
3
8
(18 mm)
(365 mm)
25
/
"
3
4
(654 mm)
Recommended installation clearances (dryer only)
18" min.
(457 mm)
5"
(127 mm)
1"
1"
(25 mm)
(25 mm)
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Side view:
50
"
7
/
8
(1292 mm)
3
/
"*
4
(18 mm)
6
"
1
/
4
(159 mm)
NOTE: Most installations require a
minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with
29
/
"*
7
8
elbow. See "Venting Requirements."
(759 mm)
3
1
/
"*
2
(89 mm)
6
/
"*
1
8
(156 mm)
* Approximate measurement
3"
(76 mm)
48 in.
min.
2
(310 cm
)
2
For closet installation, with a
door, the minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
air ventilation openings are
24 in.
min.
2
(155 cm
)
2
acceptable.
3"
(76 mm)
31
1
/
"
8
(790 mm)
5
"*
3
/
4
(146 mm)
Ref. W10057364B
12/2010