- ページ 6

換気フード Whirlpool (91.) BUILT-INのPDF 設置および使用マニュアルをオンラインで閲覧またはダウンロードできます。Whirlpool (91.) BUILT-IN 24 ページ。 36" (91.4 cm) gas built-in cooktop
Whirlpool (91.) BUILT-IN にも: 取付説明書 (16 ページ)

Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) Vent System
Vent Piece
45° elbow
90° elbow
6" (15.2 cm)
wall cap
3 " x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm)
3 " x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) 90° elbow
Example vent system
90˚ elbows
3¼" x 10"
(8.3 x 25.4 cm)
to 6" (15.2 cm)
transition
Maximum Recommended Length
1 - transition
2 - 90° elbows
1 - wall cap
8 ft (2.4 m) straight
Length of 6" (15.2 cm) system
6
6" (15.2 cm) Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
6 ft
Wall cap
(1.8 m)
2 ft (0.6 m)
= 26 ft (7.9 m)
= 4.5 ft (1.4 m)
= 10.0 ft (3.0 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 22.5 ft (6.9 m)
" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3 " x 10" (8.3 cm x 25.4 cm)
90° elbow
3 " x 10" (8.3 cm x 25.4 cm)
flat elbow
3 " x 10" (8.3 cm x 25.4 cm)
wall cap
Example vent system
3 " x 10"
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 3 " x 10" (8.3 cm x 25.4 cm)
system
" x 10" (8.3 cm x 25.4 cm)
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
Wall cap
= 26 ft (7.9 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)