換気フード Whirlpool 883243のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Whirlpool 883243 7 ページ。 30” and 36” retractable downdraft vent systems
Ductwork installed under a concrete slab using
PVC sewer pipe.
Optional ductwork installed under a concrete slab
into a window well.
Do
not vent a
gas
cooktop into a window well,
12" minimum
6"
round PVC
concreie
slab
transition
6" round metal duct
6" round
T
6" min.
I
PVC sewer
Tiahtlv
oock
pipe elbow
6" rouhd
'-G----I
r --.-
PVC
gravel or sand
completely
coupling
around pipe.
Seal the space between the outside of wall
cap inlet inside of PVC coupling with
caulking metal.
Maximum
length of ductwork
system
For best performance,
use no more than
three 90" elbows.
If more than one elbow
is
used, make sure that there is a minimum
of
24 inches of straight duct between
any two
elbows.
Do Not install two elbows
together.
It is recommended
that you use round duct
instead
of rectangular
duct, especially
if
elbows
are required.
If rectangular
duct is
required,
it should be transitioned
to 6"
round duct as soon as possible.
Determining
the length of system
you need
To calculate
the length
of system you need,
add the equivalent
feet for each duct
piece that will be needed.
See example
for
6" round ductwork
system.
6" round ductwork
system
6ft. -4
lb
Maximum
length
= 25 ft.
I-wallcap
=
0
feet
8 feet straight
=
8
feet
2 - 90" elbows
=
10
feet
Transition
=
4.5
feet
Length of 6" system =
22.5
feet
Recommended
standard
fittings
:::::::;
..::::: . . . . . -.- . . . . . -.
:i::
...-...-.-.-.-.-.-..i
. ..-.-.-.-..-...
:
..i-I~~~ ~~~
...~~~:-.
.::.:::.:>.:::;
.-:..
3-l/&x
10"
3-l/$x
lO"to6"
6"f;63-1/4"xlo"
to 6" = 4.5 ft.
90" elbow
= 5 ft.
90" elbow = 9 ft.
PO; ;,lbow
Now start...
With downdraft
vent in kitchen.
1
n
Put on gloves and safety glasses.
Place cardboard
or another
form of
protection
on top of a flat surface where
you can easily assemble
the downdraft
vent system. Remove
parts packages,
downdraft
vent and blower
box from
carton.
Remove
all shippina
materials,
tape
and protective
film fro'& downdraft
vent
and blower
box.
2
w
Attach
one
overcounter
mounting
bracket
to
each side of the
downdraft
vent with
flange
side out.
3
w
Attach
supper? legs to side of
downdraft
vent with two screws in each leg.
Do Not tighten
screws.
Injury Hazard
Use two or more people to move and
safely install vent system.
Failure to follow this instruction
can result
in back or other injury.
4
w
Carefullv
insert downdraft
vent into
countertop
cut&t.
Two people
are
recommended
to support the weight
of the
downdraft
vent during lifting. Check that
downdraft
vent is parallel
to side of cutout
and that mounting
brackets
overlap
countertop.
w
Move support
legs down against
cabinet
floor. PI&e
a le;el against-front
of
downdraft
vent base and adjust until
downdraft
vent is level vertically.
Use a
pencil to mark the top of each leg on face
of downdraft
vent. Then mark location
of
support
leg mounting
holes on cabinet
floor. Remove
downdraft
vent from cutout.
Drill starter holes at each
mounting
screw
location
on cabinet
floor. Align top of legs
with pencil
marks on face of downdraft
vent. Tighten screws in legs.
If blower
box is removed
from vent base,
check
that wiring cable
is properly
secured
in plastic clips.
6
H
Determine
which
direction
(down
or
rear) ductwork
will need to run from blower
duct when installed
in cabinet.
Down venting:
Downdraft
vent is shipped
with blower
in
down venting
position
so no modification
is
required.
Go to Step 7.
left or right venting:
a. Remove
4 hex nuts that attach
blower
box to downdraft
vent base. Remove
blower
box.
b. Rotate blower
box 90" to left or right so
that vent blower
is repositioned
in the
direction
needed.
c. Reattach
blower
box to downdraft
vent
base with 4 hex nuts.
Rear venting:
a. Remove
4 hex nuts that attach
blower
box to downdraft
vent base. Remove
blower
box.
b. Note how wiring cable
is installed
under
plastic clips inside vent base. Then carefully
remove
wiring cable
from plastic clips.
Disconnect
blower
wiring cable.
c. Remove
6 Phillips-head
screws attaching
blower
to blower
box. Remove
blower.
bracket
for
real venting
\
d. Remove
screws attaching
brackets
to
each side of blower.
Reposition
brackets
on
blower
as shown. Then reinstall screws.
e. Reinstall blower
in blower
box with mouth
of blower
pointing
out open side of blower
box. Secure blower
to blower
box with 6
Phillips-head
screws.
NOTE: Square metal frame attached
to
mouth of blower
must be installed
for
proper
operation.
f. Attach
metal cover from parts bag over
down-venting
knockout
in blower
box.
Remove
rear knockout
cover on back of
vent base.
g. Reconnect
blower
wiring cable.
Secure
wiring cable
in 2 black plastic
clips inside
vent base. Reattach
blower
box to
downdraft
vent base with 4 hex nuts.
7
w
Attach
backdraft
damper
over
blower
box knockout
with 2 Phillips-head
screws.
8
n
Remove
the 2 Phillips-head
screws
attaching
appliance
wirini
box cover.
Determine
which
direction
(rear or down)
electrical
connection
will need to run from
appliance
wiring box. Knock out rear or
lower wiring opening
in wiring box.
Panel
C