4. Install the right and left undercounter mounting brackets to
the vent box. Slide the keyhole slots over the guide tabs and
push the brackets up to set them into place.
A. Vent box
B. Undercounter mounting bracket
C. Keyhole slots
D. Guide tabs
5. Attach the right and left end caps to the vent box. Place the
tab into the mounting slot at each end of the downdraft vent
as shown and push down to lock into place.
A. End cap tab
B. Mounting slot
6. Measure distance "X" from the cabinet floor to the top of the
countertop. Subtract 28¹⁄₂" from distance "X" to determine
dimension "Y" (X - 28¹⁄₂ = Y).
Downdraft vent
28¹⁄₂"
(73 cm)
10
B
A
C
D
A
B
Top of countertop
"X"
"Y"
Cabinet floor
7. Attach the support legs to the side of the vent box with
4 - 4 x 8 mm screws in each support leg. Adjust to dimension
"Y" from the bottom of the vent box to the bottom of the
support legs. Tighten screws.
A
A. Motor box
B. Support leg
C. 4 x 8 mm screws (4)
Determine Which Vent Direction Is Best For Your
Installation
When installed in a cabinet, vent system can exhaust through the
bottom, right or left of the cabinet.
IMPORTANT: When using the 6" (15.2 cm) vent transition
(supplied) for 6" round venting, only left or right venting is
recommended.
Bottom Venting:
NOTE: If installing the vent damper in the down position, a wall or
roof cap with a damper at the exit end of the vent system is
required.
Downdraft vent is shipped with blower in down venting
position so no modification is required.
If rear mounting of the blower motor is not required, go to
the "Complete Installation" section.
To mount the blower motor to the rear side of the vent
box, go to the "Rear Mounting - Blower Motor" section.