- ページ 3
換気フード Whirlpool UXD8636DYのPDF 製品寸法をオンラインで閲覧またはダウンロードできます。Whirlpool UXD8636DY 3 ページ。 30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Whirlpool UXD8636DY にも: 取扱説明書 (36 ページ)
Rear Mounted Blower Motor
B
A
C
M
L
K
J
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent transition with damper (supplied)
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 6" (15.2 cm) round 90° PVC sewer pipe elbow
L. 6" (15.2 cm) round PVC coupling
M. 12" (30.5 cm) minimum
Calculating Vent System Length
3 " x 10" (8.3 x 25.4 cm) rectangular vent is required from the blower
motor box. It can be transitioned to 6" (15.2 cm) round vent if needed.
Maximum Length of Vent System
Vent
6" (15.2 cm) round
3 " x 10" (8.3 cm x 25.4 cm)
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent
3 " x 10" (8.3 cm x 25.4 cm) 5.0 ft
90° elbow
3 " x 10" (8.3 cm x 25.4 cm)
flat elbow
3 " x 10" (8.3 cm x 25.4 cm)
wall cap
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
D
E
F
G
H
I
Length
35 ft (8.9 m)
35 ft (8.9 m)
3 " x 10" (8.3 cm x 25.4 cm)
Rectangular
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
Vent Piece
45° elbow
90° elbow
6" (15.2 cm)
wall cap
3 " x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) transition
6" (15.2 cm) to 3 " x 10"
(8.3 cm x 25.4 cm) transition
3 " x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) 90° elbow
transition
6" (15.2 cm) to 3 " x 10"
(8.3 cm x 25.4 cm) 90° elbow
transition
Example vent system
C
B
A
The following example falls within the maximum vent length of 35 ft
(8.9 m).
2 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Transition
Length of 6" (15.2 cm) or
3 " x 10" (8.3 cm x 25.4 cm)
system
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
6" (15.2 cm) Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
1 ft
(0.3 m)
5.0 ft
(1.5 m)
5.0 ft
(1.5 m)
6 ft
(1.8 m)
2 ft (0.6 m)
D
A. Blower motor
B. Transition
C. 90° elbows
D. 6" back draft damper (supplied)
= 10.0 ft (3 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 4.5 ft (1.4 cm)
= 22.5 ft (6.8 m)
Page 3 of 3