- ページ 6

換気フード Whirlpool UXT4836AAB0のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Whirlpool UXT4836AAB0 28 ページ。 30" (76.2 cm) and 36" (91.4 cm) range hood

Whirlpool UXT4836AAB0 取扱説明書
Calculating
Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
7" (17.8 cm) Vent System
Vent Piece
7" (17.8 cm) Round
45 ° elbow
2.5 ft
(0.8 m)
3Y4"x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
31/4"x 10" (8.3 cm x 25.4 cm)
5.0 ft
90 ° elbow
(1.5 m)
31/4"x 10" (8.3 cm x 25.4 cm)
12.0 ft
flat elbow
(3.7 m)
90 ° elbow
5.0 ft
(1.5 m)
31/4"x 10" (8.3 cm x 25.4 cm)
0.0 ft
wall cap
(0.0 m)
7" (17.8 cm)
0.0 ft
wall cap
(0.0 m)
3%" x 10" (8.3 cm x 25.4 cm)
4.5 ft
to 7" (17.8 cm)
(1.4 m)
3%" x 10" (8.3 cm x 25.4 cm)
5.0 ft
to 7" (17.8 cm) 90 ° elbow
(1.5 m)
Example vent system
90° elbow
Wall cap
o. (18
.................
rn)
Maximum Recommended
Length
= 50 ft (15.2 m)
1 - 90 ° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
Example vent system
31/4" xlO"
(8.3 x 25.4 cm)
elbow
6 ft (1.8
rn)
/
Maximum Recommended
Length
Wall cap
= 35 ft (10.7 m)
1 - 90 ° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 31/4 '' x 10" (8.3 cm x 25.4 cm)
system
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)
6