- ページ 8
換気フード Whirlpool WVW75UC6DSのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Whirlpool WVW75UC6DS 28 ページ。 36" (91.4 cm) island-mount canopy range hood
Whirlpool WVW75UC6DS にも: 取扱説明書 取付説明書 (28 ページ), 取扱説明書 (32 ページ)
Install In-Line Smart Kit - Optional
NOTE: Your range hood can work with either an internal or an
inline (external) blower motor system. An optional In-Line Smart
Kit (purchased separately) allows the blower motor that comes
with this range hood to be installed in a location other than
inside the range hood cavity.
CAUTION: To reduce the risk of fire and electric shock, install
this range hood only with the In-Line Smart Kit manufactured
by Whirlpool, Part Number W10692945.
For installation see the In-Line Smart Kit installation instructions.
See the "Assistance or Service" section to order.
Install Range Hood
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
B
A
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Connect Vent System
1. Install transition on top of hood (if removed for shipping)
with (2) 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
8
For vented installations only:
1. Fit vent system over the exhaust outlet.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket
using (4) 4.2 x 8 mm screws.
C
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
3. Cut the duct to the measured size "X."
4. Remove the air deflector.
5. Slide the duct onto the bottom of the air deflector.
6. Place the assembled air deflector and duct over
the exhaust outlet from the hood.
7. Reassemble the air deflector to the duct cover bracket
with the 4 assembly screws.
8. Seal connections with vent clamps.
B
C
A. Assembly screws
B. Air deflector
C. Duct cover bracket
A
B
X
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
A
C