- ページ 4
サーモスタット Clare Controls CH-THSTAT-WのPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。Clare Controls CH-THSTAT-W 15 ページ。 Wi-fi thermostat
Clare Controls CH-THSTAT-W にも: インストレーション・マニュアル (10 ページ)
Setting Fan Mode and System Status Indicators
System
Status
Indicators
Press the Fan button to change the Fan mode
AUTO FAN: Fan automatically operated by the HVAC system.
•
FAN ON: Manual Fan mode. Fan stays on until mode is changed back to Auto.
•
Optional Fan Mode
Fan Cycler. If the Fan Cycler feature is enabled in the Installer Setup, the additional fan
mode "Cycle" will be shown in the Fan Mode menu. This mode cycles the fan on and off
continuously for fresh air ventilation according to the settings in the Installer Setup.
System Status Indicators
When the main thermostat screen is displayed, the on-screen labels indicate the following.
System Operation mode indicator
"SYS OFF" displayed > System is OFF
1
"SYS MOT"
displayed > System is OFF and Minimum Off Time (MOT) delay On is active
"HEAT ON" displayed > System is ON and heating
"COOL ON" displayed > System is ON and cooling
2
"HEAT MRT"
displayed > System is ON and heating. Minimum Run Time (MRT) delay off
is active.
"COOL MRT" displayed > System is ON and cooling. Minimum Run Time (MRT) delay off
is active.
Staging display
nd
"2
Stg" displayed > Stage 2 heating or cooling is ON
"Aux Heat" displayed > Stage 3 heating is ON
For Heat Pump systems only: "EHEAT" > emergency heat mode active
Home/Away display
Home mode is active (current setpoints are being used)
Away setback mode is active (setback setpoints are being used)
System Alerts
Alert Messages:Filter or Maintenance Timer
WiFi Network connection Status: No Link, Link OK, TCP
Notes 1 and 2: See MOT and MRT descriptions on page 5
Doc ID 2014-05-223 • Rev 02
4:30 PM
75
Cool
Fan On
Hold
Link Ok
HEAT
AUTO
MODE
FAN
MENU
RH 40%
64H
82C
HOLD
Page 4