CARE AND MAINTENANCE
CLEANING:
• Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
• Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
• Clean intake and exhaust vents by wiping with a dry, soft cloth.
FILTER REPLACEMENT:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon filters. The replacement period will vary depending on
the hours of use, air quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 1 year, and Carbon
filter every 6 months. When a filter needs to be replaced the following color will be shown on any one of the HEPA or CARBON filter replacement
indicators:
Amber flashing = 90% filter wear (recommendation to order new filters)
Red = 100% filter wear (replace with new filters)
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax
function using any other replacements.
FILTER REPLACEMENT PROCEDURE:
1
Press the access panel latch down while
pulling front panel towards you.
FILTER LIGHT RESET:
When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset any
of the filter replacement indicators, press and hold filter type button that was replaced (HEPA or Carbon) until the light turns off. Repeat for other filter types as
needed. When replacing the hybrid filter, reset both the HEPA and carbon indicator lights.
TROUBLESHOOTING
PROBLEM:
The air quality control system fails to start.
The unit makes a faint ticking sound.
The HEPA and/or Carbon Filter replacement indicator light
remain lit after replacing the filter(s).
2
Remove old filter(s).
POSSIBLE SOLUTION:
• Check to assure unit is connected to power supply.
• Make sure filters are genuine AeraMax
brands. IMPORTANT: Make sure to align the AeraMax PRO Certified Stickers on the filter
and the inside of the unit. The arrows should point towards the back of the unit.
• Review Filter Replacement Method section for further detail.
• Make sure front access panel is closed completely.
• Make sure power switch is on.
• This indicates that the "PlasmaTRUE™" bipolar ionizer is working.
• Repeat filter light reset instruction.
®
PRO brand replacement filters as units will not
3
When inserting new filters, be sure to remove
the plastic bag. When inserting new Hybrid
or HEPA filters, align the AeraMax
Certified Filter stickers on the filter and the
inside of the unit. The arrow should point
towards the back of the unit.
Reference (4) on the KEY section.
®
PRO filters, as unit will not function with other
®
PRO
7