セキュリティシステム Alderon Industries Versa'larm VA01DのPDF 操作、メンテナンス、設置マニュアルをオンラインで閲覧またはダウンロードできます。Alderon Industries Versa'larm VA01D 4 ページ。 1-zone alarm
Versa'larm
1-Zone Alarm - Model VA01D | Manual Silence
Operation, Maintenance and Installation Manual
Introduction of Installation
Safety Guidelines
1. DISCONNECT ALL ELECTRICAL SERVICE BEFORE INSTALLING OR WORKING ON THE PRODUCT.
2. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC.
DO NOT USE IN EXPLOSIVE ATMOSPHERES.
3. ALARM PANEL MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS CONSULT FACTORY.
Description of Operation
The 1-Zone Manual Silence Versa'larm™ alarm panel is powered by 120 VAC coming from standard wall outlets and is
transformed to 9-11.1 VDC. Installing a 9 Volt battery provides battery backup during power outages. The power LED
(green) will illuminate when powered. The Manual Silence Versa'larm™ is a multipurpose alarm panel that can be use in a
variety of applications such as: septic tanks, sumps, holding tanks, pump chambers, water tanks, flow, pressure, conden-
sate, temperature, and any others where a "dry contact" can be connected to the alarm panel.
When a switch (signaling device) contact "closes" the buzzer will annunciate, alarm and silence LEDs (red) will illuminate,
and the built in auxiliary contacts will be activated. The signaling device could be a float switch, water sensor, or sump probe
sensor. The auxiliary contacts can be used to connect to an Alderon Industries Auto Dialer, an existing alarm security
system, or building automation system (BAS).
Slide the manual switch to the "S" (Silence) position, this will silence the buzzer while the alarm and silence LEDs (red)
remain on. When the alarm condition is cleared, slide the manual switch to the "N" (Normal) position, this will automatically
reset the system for the next alarm cycle.
Tools, Supplies and Requirements for Installation - Not Included
1. Phillips screw driver
2. (Qty 2) #6 self tapping screws
3. Access to 120 VAC power receptacle
4. Optional - Plastic anchors (#8; Qty 2) if mounting to sheet rock
5. Optional - 9V battery (used for battery backup during power outages)
6. Optional - Wire stripper (used if you need to strip wire to connect to a BAS or SCADA system)
7. Optional - Needle nose pliers if using auxiliary contacts
Alarm Systems
Control Panels
Alderon Industries - Hawley, MN | 218.483.3034 | [email protected] | alderonind.com
™
Before proceeding with the installation or operation of the product, read all
instructions thoroughly, as well as complying with all federal, state and local
codes, regulations, and practices. The product must be installed by qualified
personnel familiar with all applicable local electrical and mechanical codes.
Refer to the National Electrical Code (NFPA 70). Failure to properly install and
test this product can result in personal injury or equipment malfunction.
Float Switches
Leak Detection Systems
Page 1 of 4