- ページ 6
サーモスタット eControls C365T11のPDF インストーラーとユーザーマニュアルをオンラインで閲覧またはダウンロードできます。eControls C365T11 13 ページ。
eControls C365T11 にも: ユーザーマニュアル (4 ページ), インストーラーとユーザーマニュアル (13 ページ)
INSTALLER OPTIONS
Option
Description
01
Compressor Stages
02
Heating Stages
03
Fan Operation. (Only displayed if GE selected)
04
Compressor Minimum Off Time (minutes).
05
Gas Heating Minimum Off Time (minutes).
06
Minimum Run Time (minutes).
07
On-Off Temperature Differential
o
0 Cool On 1 above setpoint, Off at setpoint. Heat On1 below setpoint, Off at setpoint.
o
1 Cool On 1 above setpoint, Off .5 below setpoint. Heat On1 below setpoint, Off .5 above setpoint.
o
2 Cool On 1 above setpoint, Off 1 below setpoint. Heat On1 below setpoint, Off 1 above setpoint.
08
Smart Recovery.
09
Vacant Heating Setpoint.
10
Vacant Cooling Setpoint.
11
Calibrate Living Area Sensor
12
Calibrate Sleeping Area Sensor.
13
Airflow Update Time
14
Night Level LCD Backlight
15
Airflow Control
16
User (Manual) Airflow Control Enabled
17
Maximum Airflow in Heating to the Sleeping Space.
18
Maximum Airflow in Cooling to the Sleeping Space.
Maximum Airflow in Heating to the Living Space.
19
Maximum Airflow in Cooling to the Living Space.
20
Maximum Temperature Difference Between
21
Sleeping and Living Spaces.
22
Factory Restore
ACCESSING INSTALLER OPTIONS
To access the Installer Options,
TOUCH
HOLD
the hidden Enter key for 7 seconds until
the first Option appears on the screen.
Sleeping
Airflow %
Schedule
Living
Day
Tu
AM
MENU
MODE
TOUCH
and
The hidden BACK
for 7 seconds to access the
key can be used to
Installer Options.
return to previous
options.
INSTALLER SECTION
Display
o
o
V A C
V A C
C A L
C A L
BL + Night
HAF + Heat
CAF + Cool
HAF + Heat
CAF + Cool
Press the touchscreen with your fingertip
!
only, using a firm touch. Do not use a sharp
and
object such as a pen or pencil.
!
The NEXT key is used to display the next
option.
The ENTER key is used to save options and
!
return to normal thermostat operation.
Cool
Set To
The hidden BACK key is used to return to
!
previous options and is located to the left of
Living
COOL
the NEXT key.
SYSTEM
AUTO
FAN
01 Set Compressor Stages
HOLD
this key
Factory Default: 1. Range: 0 or 1
Use the UP/DOWN
keys to set 0 or 1
stage.
Touch NEXT or
ENTER.
Range
CPr
0 or 1
HtG
0, 1 or 2
FAn
GA(Down) or EL(Up)
COt
0 to 9
0 to 9
HOt
r n t
0 to 9
o
O O
0, 1 or 2
o
o
o
o
S r
0n(Up) or Off(Down)
+Heat
44 to 75F
+Cool
74 to 95F
+/- 5F
+/- 5F
AFt
1 to 20 minutes
On(Up) or Off(Down)
AFC
On(Up) or Off(Down)
UAC
On(Up) or Off(Down)
100 to 160%
100 to 160%
100 to 160%
100 to 160%
dIF
0 to 100
Fr
No(Next or Enter) or Yes(UP key then Enter)
Option
NEXT
ENTER
Page 6 of 16
Default
1
1
GA
2
0
2
1
o
Off
65F
80F
na
na
2
On
On
On
160%
150%
160%
150%
2
No
02 Set Heating Stages
Factory Default: 1. Range: 0 or 1.
Use the UP/DOWN
keys to set 0 or 1
stage.
Touch NEXT or
ENTER.
03 Setting the Fan Operation
Factory Default: Gas. Range: GA or EL
Use the UP key to
select "EL" for
electric operation
where the
thermostat activates
the indoor fan (G
terminal) during heating calls or DOWN key to
select GA for gas operation where the equipment
plenum sensor activates the indoor fan in heating
calls.
Touch NEXT or ENTER.
Set To
na
Option
NEXT
ENTER
Option
NEXT
ENTER