サーモスタット eControls Comfort365 C365C32のPDF インストーラー・マニュアルをオンラインで閲覧またはダウンロードできます。eControls Comfort365 C365C32 4 ページ。 Wiring hub, model wh11 and wh32
eControls Comfort365 C365C32 にも: インストーラー・マニュアル (8 ページ)

Comfort
Optional eLink Radio Module plugs into connectors.
24VAC Power Indicator.
Terminals for wiring
to HVAC equipment.
Terminals for Upstairs wired
temperature sensor.
Terminals for optional outdoor
Description
The Wiring Hub is installed at the equipment. It is connected
to the C365C32 or C365C32WF thermostat using the existing
or new 4-wire thermostat cable that normally connects the
thermostat to the equipment. The equipment is wired directly
to the Wiring Hub. The upstairs sensor can be either a wired
or wireless sensor. Wireless sensors use the ELR1 Radio
Module that plugs into the Wiring Hub. An outdoor
temperature sensor can also be used to control fossil fuel
heating in a dual fuel heat pump (WH32 only).
Compatible Equipment, WH11
Gas/Electric equipment with 1 heat/ 1 Cool.
Compatible Equipment, WH32
Gas/Electric equipment, conventional and dual fuel heat pump
equipment with 3 heat/ 2 Cool.
Power
Powered by 24VAC from the equipment R and C terminals
Warranty
This wiring hub is warranted to be free of defects due to
workmanship or materials under normal use and service for a
period of 5 years from date of installation and not longer than
6 years from manufacturing date code.
365
EQUIPMENT
temperature sensor.
Wiring Hub, Model WH11 and WH32
Cover.
LIVING
SLEEPING
DAMPER
DAMPER
THERMOSTAT
Connector for Upstairs Plug&Play
Modulating Damper.
Connector for Downstairs Plug&Play
Modulating Damper.
Terminals for wiring to
Comfort365 Thermostat.
Power Indicator
LED indicator.
Damper Actuators
Uses A80MJ Plug&Play damper Actuators. Up to 6 dampers
can be daisy chained to define the Upstairs or Downstairs
space.
Wired Upstairs Temperature Sensor
One or two wired sensors can be used in the Upstairs space.
For single sensor installations use TS510W sensor. For two-
sensor installations, use the TS520W sensor.
Wireless Upstairs Temperature Sensor
One or two battery powered, wireless sensors can be used.
The ELR1 Radio Module must be installed in the Wiring Hub
when wireless sensors are used. Use the TS5WL sensor for 1
or 2-sensor installations.
eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653
949-916-0945 Fax 949-458-8502 www.eControlsUSA.com
Installer Manual
Ver 2.0 Jun 2017
Screw attaches cover to base.
eControls
eControls