- ページ 8
コントローラー eControls RT2のPDF ユーザー&インストーラーズマニュアルをオンラインで閲覧またはダウンロードできます。eControls RT2 8 ページ。 Wireless whf control
eControls RT2 にも: 住宅所有者とインストーラー・マニュアル (12 ページ)
1
Set the FAN Number
The RT2 and the RM2 are factory set to FAN 1. If only using
one WHF, proceed to Option 2. Up to 8 WHFs can be used in a
home. Each fan must be set to a different Fan number so that
the RT2 only controls the WHF with the corresponding number.
The fan number must be set at the RT2 and at the RM2.
Setting Fan Number on RT2 Thermostat
Access Installer Options by pressing and
holding the MENU key for about 7 seconds
until Option 01 is displayed. Use the UP or
DOWN key to change the fan number and
Option
then press the ENTER key.
Next
Enter
Setting Fan Number on RM2 Radio Module
ODT
ODT
Press here to set the
Fan number.
2
Set the ADDRESS Number
When neighbors are using the wireless RT2 thermostat, the
RT2 and RM2 must be set to different ADDRESSES (ADR) if
the homes are within 300 feet on one another. This insures
that an RT2 does not control a neighbors WHF.
Setting ADR Number on RT2 Thermostat
Access Installer Options by pressing and
holding the MENU key for about 7 seconds
until Option 01 is displayed. Press the
NEXT key to display Option 02 and use the
Cool
Option
UP or DOWN key to change the Address
number and then press the ENTER key.
Next
Enter
Setting ADR Number on RM2 Radio Module
ODT
ODT
Press here to set the
Address number.
INSTALLER SECTION
Use a paper clip to push the
internal switch. When
pressed the LED will blink
green once, pause, blink
twice, etc.
For example, to set the fan to
number 3, release the switch
after the LED rapidly blinks 3
times.
Use a paper clip to push the
internal switch. When
pressed the LED will blink red
once, pause, blink twice, etc.
For example, to set the
Address to number 3, release
the switch after the LED
rapidly blinks red 3 times.
3
Set the Type of WHF
The type of WHF is set on the RT2 thermostat by the installer
using the Installer options. Access Installer Options by
pressing and holding the MENU key for about 7 seconds until
Option 01 is displayed. Press the NEXT key until Option 03 is
displayed.
Use the UP or DOWN key to change the
type of WHF:
01 = Single Speed WHF
02 = Two Speed WHF
Option
EC = ECM Variable Speed
Select 01 for a single speed PSC or ECM
fan. Single speed fans are connected to
Next
Enter
the High speed output. Press ENTER to
save as single speed fan or press NEXT to
go to two speed or variable speed fan
selection.
Select 02 for a two speed PSC or ECM fan.
Press ENTER to save as single speed fan
or press NEXT to go to two speed or
variable speed fan selection.
Option
Enter
Next
Select EC for a variable speed ECM fan.
Fan speed in variable speed ECM fans is
controlled by a PWM signal and can be
selected in 5% increments from 20% to
Option
100%.
When the speed is increased or the fan
turned on in a variable speed ECM fan, the
speed ramps up for quieter operation.
Next
Enter
Press ENTER to save as single speed fan
or press NEXT to go to two speed or
variable speed fan selection.
Limited 5-Year Warranty
The 5-year warranty is limited to the repair or replacement of
defective product due to parts failure or defective workmanship.
26072 Merit Circle #110 / Laguna Hills, CA 92653
949-916-0945 Fax 949-458-8502
eControls
eControls
www.eControlsUSA.com