- ページ 8
楽器 Yamaha Silent Cello SVC210のPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Yamaha Silent Cello SVC210 30 ページ。 Silent electric cello
Yamaha Silent Cello SVC210 にも: オーナーズマニュアル (15 ページ), オーナーズマニュアル (16 ページ)
SVC210
I DISASSEMBLY PROCEDURES (分解手順)
Preparation
Before disassembling, perform the following procedure.
•
Remove the chest support and arm rest. (Fig. 1)
•
Hold the knee supports opened. (Fig. 2)
•
Remove the battery from the battery case.
•
Remove the bridge and all strings.
•
Remove the tailpiece and tail nylon. (Fig. 3)
Arm rest
(腕当て)
1.
Control Panel Unit
(Time required: about 2 min.)
1-1
Remove the eight (8) screws marked [S70]. (Fig. 4)
1-2
Disconnect the cord of the pickup assembly from the
connector on the MA circuit board.
The control panel unit can then be removed. (Fig. 5)
2.
MA Circuit Board
(Time required: about 3 min.)
2-1
Remove the control panel unit. (See procedure 1.)
2-2
Remove the six (6) screws marked [CA40] and the two
(2) screws marked [CA50A]. (Fig.6)
2-3
Remove the VR knob marked [CA110].
The MA circuit board can then be removed. (Fig. 4)
8
Chest support
(胸当て)
(Fig. 1)
Knee supports
(ひざ当て)
(Fig. 2)
準備
分解を始める前に、以下の作業を行います。
・ 胸当てと腕当てを外します。 (Fig. 1)
・ ひざ当てを開いた状態で固定します。 (Fig. 2)
・ 電池ケースから電池を取り出します。
・ 駒 (ブリッジ) とすべての弦を外します。
・ テールピースとテールナイロンを外します。 (Fig. 3)
(Fig. 3)
1.
コントロールパネルユニット
(所要時間:約2分)
1-1
[S70] のネジ8本を外します。 (Fig. 4)
1-2
ピックアップAss'yの束線をMAシートのコネクタから
外し、コントロールパネルユニットを外します。
(Fig. 5)
2.
MAシート (所要時間:約3分)
2-1
コントロールパネルユニットを外します。 (1項参照)
2-2
[CA40] のネジ6本と [CA50A] のネジ2本を外します。
(Fig. 6)
2-3
[CA110] のVRノブを外し、MAシートを外します。
(Fig. 4)
Bridge
(駒「ブリッジ」)
Tailpiece
(テールピース)
Tail nylon
(テールナイロン)