- ページ 6
楽器 Yamaha SILENT Piano YUS5SGのPDF メンテナンス・ハンドブックをオンラインで閲覧またはダウンロードできます。Yamaha SILENT Piano YUS5SG 14 ページ。 Upright piano
3. Piano regulation caution
1) Removing the Lower Front Board
The switch box obstructs removal of the lower
front board. Use the procedure shown on the
right and remove the switch box before removing
(opening) the lower front board.
1) Disconnect the three lines on the rear of the
switch box.
2) Loosen the three attachment screws, and then
slide the switch box forward to remove.
2) When Tuning
Since the shank stopper impedes use of the
wood mute when tuning the treble strings, the
TX600250 mute is specially designed for this
purpose and offers easy use.
3)Attaching/Removing the Action
4) When removing the keyboards
When removing the keyboards, be careful not to break
the key shutter attached to the keyboard. Also, when
placing the removed keyboard on the floor, be careful not
to break the key shutter.
*When removing the keyboards, be careful not to touch
the key shutter.
Key shutter:
Remove the key shutter from the keyboard. Pull the key
shutter while slightly slanting it.
* When inserting the key shutter, also slant and insert it.
Use the TX645600 lifting rod setter to
attach the damper pedal rod.
6
Fig.5
Fig.6
Fig.7
Fig.8