- ページ 9
ラック&スタンド CALI ALS600T-AD-AA-BM SeriesのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。CALI ALS600T-AD-AA-BM Series 11 ページ。
CALI ALS600T-AD-AA-BM Series にも: インストレーション・マニュアル (2 ページ)
1.
Measure area where luminaire will be installed. Use a chalk line to ensure a straight installation.
2.
Mark location where mounting clips will be installed. Quantity of mounting clips = quantity
of fixture +1. Use a mounting clip at the joint between two fixtures (for dry location only).
3.
Lay mounting clips and pre-drill using proper drill bit for surface and screw size.
Recommendation: 8/32 x 1" screw.
Note: Allow 0.25" clearance for lateral expansion of assembled mounting clips.
Only install mounting clips on flat, even surfaces.
4.
If applicable, connect disconnects between fixtures. Push and twist cap to lock connector.
Note: Shrink tube required for wet location installations.
5.
Screw mounting clips to surface, then snap fixture into mounting clips. Install set screws if
necessary. Set screws required for downward and outward facing applications.
Set Screw
6.
Perform continuity test steps on page 10 before connecting fixture to power source.
CALIFORNIA ACCENT LIGHTING, INC.
2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
2019.12.5 Rev 2
4'
Mounting Clip
2"
2"
3'
2"
2"
2'
2"
2"
1'
2"
2"
Shrink Tube
Apply Heat
ALS600T-AD
alumLEDs
Manufactured in the U.S.A.
Page 9 of 11
INSTALLATION
Mounting Fixture
™