- ページ 6

ホブ Zanussi ZGG66424のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Zanussi ZGG66424 16 ページ。 Gas hob
Zanussi ZGG66424 にも: ユーザーマニュアル (16 ページ), ユーザーマニュアル (16 ページ), ユーザーマニュアル (21 ページ)

Zanussi ZGG66424 ユーザーマニュアル
Electrical Requirements
Permanent electrical installation must comply with the lat-
est I.E.E. Regulations and local Electricity Board regula-
tions. For your own safety the installation must be done
by a qualified electrician (e.g. your local Electricity Board,
or a contractor who is on the roll of the National Inspec-
tion Council for Electrical Installation Contracting [NICE-
IC]).
The manufacturer declines any liability if these safety
measures are not observed.
The appliance must be connected to a 230 V 50 Hz AC
electrical supply.
Before activating the appliance, make sure the electrical
supply voltage is the same as that indicated on the rating
plate. The rating plate is located on the bottom of the ap-
pliance.
The appliance is supplied with a 3 core flexible supply
cord with a 3 amp plug. If it is necessary to change the
fuse, use a 3 amp ASTA-approved (BS 1362) fuse.
1
5
Green and Yellow
1
3 amp fuse
2
Brown
3
Cord clamp
4
Blue
5
Should the plug need to be replaced for any reason, the
wires in the mains lead are coloured in accordance with
the following code:
Green and yellow
Blue
6
2
3
4
- Earth
- Neutral
Brown
1.
Connect the green and yellow (earth) wire to the ter-
minal in the plug which is marked with the letter 'E'
or the earth symbol
low.
2.
Connect the blue (neutral) wire to the terminal in the
plug which is marked with the letter 'N' or coloured
black.
3.
Connect the brown (live) wire to the terminal in the
plug which is marked with the letter 'L' or coloured
red.
There must be no cut or stray strands of wire present. The
cord clamp must be secured on the outer sheath.
Warning! Make sure that the cut off plug is disposed
of safely. A cut off plug put into a 13 amp socket is
a safety hazard. There is a risk of electrical shock.
Important! The replacement of the electrical cable must be
done by a qualified electrician or competent person,
according to the current regulations.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
or equivalent type. Make sure that the cable section is ap-
plicable to the voltage and the working temperature. The
yellow/green earth wire must be approximately 2 cm lon-
ger than the brown (or black) phase wire.
Building In
min. 600 mm
min. 450 mm
min. 55 mm
30 mm
10 mm
3 mm
- Live
, or coloured green and yel-
min. 650 mm
560 mm
A
11 mm
11 mm
www.zanussi.com