- ページ 8

ホブ Zanussi ZGL640TWのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Zanussi ZGL640TW 16 ページ。
Zanussi ZGL640TW にも: ユーザーマニュアル (16 ページ)

Zanussi ZGL640TW ユーザーマニュアル
If there is a fault, first try to find a solution to the
problem yourself. If you cannot find a solution to
the problem yourself, speak your dealer or the
local Service Force Centre.
These data are necessary to help you
quickly and correctly. These data are
available on the supplied rating plate.
• Model description .................
1
MOD.
PROD.NO.
SER.NO
DATA
MODEL
Stick it on Guarantee Card and send this
1
part
Stick it on Guarantee Card and keep this
2
part

Installation

Warning! Refer to "Safety information"
chapter.
Warning! The following instructions about
installation, connection and maintenance
must be carried out by qualified personnel in
compliance with standards and local
regulations in force.
Important safety requirements
This hob must be installed in accordance with
the Gas Safety (Installation and Use) Regula-
tions (Current Edition) and the IEE Wiring Reg-
ulations (Current Edition).
For appliances installed in the Republic of Ire-
land please refer to NSAI- Domestic Gas In-
8
2
MOD.
PROD.NO.
SER.NO
03 IT
DATA
MADE IN ITALY
MODEL
• Product number (PNC) .................
• Serial Number (S.N.) .................
Use the original spare parts only. They are
available at Service Force Centre and approved
spare parts shops.
Labels supplied with the accessories bag
Stick the adhesive labels as indicated below:
3
MOD.
PROD.NO.
0049
SER.NO.
Stick it on instruction booklet
3
stallation I.S. 813 Current Editions and the ET-
CI Rules for Electrical Installations.
Provision for ventilation
Detailed recommendations are contained in the
following British Standards Codes Of Practice:
B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891
Current Editions.
The hob should not be installed in a bed sitting
room with a volume of less than 20 m³. If it is
installed in a room of volume less than 5 m³ an
air vent of effective area of 100 cm² is required.
If it is installed in a room of volume between 5
m³ and 10 m³ an air vent of effective area of 50
cm² is required, while if the volume exceeds 11
m³ no air vent is required.
TYPE
230V-50Hz
IP20