- ページ 9
冷凍庫 Zanussi ZFC1042WAのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Zanussi ZFC1042WA 44 ページ。
Problem
Customer Service
If your appliance is still not working properly
after making the above checks, contact the
nearest service centre.
Installation
WARNING! Refer to Safety chapters.
Positioning
CAUTION! If you are discarding an old
appliance that has a lock or catch on
the lid, you must ensure that it is made
unusable to prevent young children
being trapped inside.
This appliance should be installed in a dry,
well ventilated indoor climate where the ambi-
ent temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Climate class
SN
+10ºC to +32ºC
N
+16ºC to +32ºC
ST
+16ºC to +38ºC
T
+16ºC to +43ºC
www.zanussi.com
Possible cause
The thickness of the frost is
greater than 4-5 mm.
The lid has been opened often.
There is no cold air circulation
in the appliance.
Ambient temperature
Solution
Defrost the appliance.
Open the lid only if necessary.
Make sure that there is cold air
circulation in the appliance.
To obtain fast service, it is essential that when
you apply for it you specify the model and
serial number of your appliance which can be
found either on the guarantee certificate or on
the rating plate located on the external right
side of the appliance.
Some functional problems might occur
for some types of models when operat-
ing outside of that range. The correct
operation can only be guaranteed
within the specified temperaturerange.
If you have any doubts regarding where
to install the appliance, please turn to
the vendor, to our customer service or
to the nearest Service Centre
The appliance shall have the plug ac-
cessible after installation.
Electrical connection
• Before plugging in, ensure that the voltage
and frequency shown on the rating plate cor-
respond to your domestic power supply.
• The appliance must be earthed. The power
supply cable plug is provided with a contact
for this purpose. If the domestic power
supply socket is not earthed, connect the
appliance to a separate earth in compliance
with current regulations, consulting a quali-
fied electrician.
• The manufacturer declines all responsibil-
ity if the above safety precautions are not
observed.
• This appliance complies with the E.E.C.
Directives.
Ventilation requirements
The airflow behind the appliance must be
sufficient.
9