- ページ 41

調理器 Zanussi ZCG5000のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Zanussi ZCG5000 48 ページ。 Gas cooker
Zanussi ZCG5000 にも: ユーザーマニュアル (40 ページ)

Zanussi ZCG5000 取扱説明書
MAIN OVEN
Heat Input
Injector Marking
Marking
SECOND OVEN
Heat Input
Injector Marking
Dual Control By-pass
GENERAL
Ignition
Spark Gap
GAS CATEGORY
1
CAT.
2H
1
CAT.
3 +
IMPORTANT - SAFETY REQUIREMENTS
This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations Current
Editions and the I.E.E. Wiring Regulations. For appliances installed in the Republic of Ireland please refer to
NSAI - Domestic Gas Installation IS813 Current Editions. Detailed recommendations are contained in the
following British Standard Codes of Practice - BS.6172, BS.5440: Part 2 and B.S.6891. All British Standards
must be 'Current Editions'.

PROVISION FOR VENTILATION

This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with the current installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current
Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as
well. For room volumes up to 5m³ an air vent of 100cm² is required: for room volumes between 5m³ and
10m³ an air vent of 50cm² is required. If the room has a door that opens directly to the outside, no air vent is
required.
For room volumes that exceed 11m³ no air vent is required.
appliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisite
air vent requirements.
Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or
more effective ventilation, for example increasing the level of mechanical ventilation where present.
Natural Gas
2.4kW (8189Btu/h)
108
69
Natural Gas
2.4kW (8189 Btu/h)
108
Fixed Internal
H. T. Spark
3-4mm
COUNTRIES OF DESTINATION
GB, IE
GB, IE
41
L.P. Gas
2.4kW (172.4 g/h)
78
78
L. P. Gas
2.4kW (172.4g/h)
78
Fixed Internal
If there are other fuel burning