BYPASS DIAMETERS
BURNER
Auxiliary
Semi-rapid
Rapid
Dual
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
Dual
Rapid
Semi-rapid
Auxiliary
GAS BURNERS FOR LPG G30 28-30 mbar
NORMAL POW-
BURNER
Dual
Rapid
Semi-rapid
Auxiliary
GAS CONNECTION
The gas pipe in the appliance has two endings. You
can connect the gas supply to either one of them.
The pipe that is not used must be clogged with the
pipe closer, which added to the appliance.
Use a fixed connections or use a flexible stainless
steel pipes in compliance with the regulation in
force. If you use flexible metallic pipes, make sure
they do not come in touch with mobile parts and
they are not squeezed.
NORMAL POWER kW
4.5
3.0
2.0
1.0
GAS RATE g/h
ER kW
4.5
3.0
2.0
1.0
Ø BYPASS 1/100 mm
REDUCED POWER kW
1.8
0.72
0.43
0.35
REDUCED POWER
327.2
218.1
145.4
72.7
29 / 30
32
42
67
INJECTOR MARK
1/100 mm
INJECTOR MARK
kW
1/100 mm
1.8
0.72
0.43
0.35
150
119
96
70
104
88
71
50
23