Operating Instructions
Switching the air compressor OFF
To switch the air compressor off,
1. Close the outlet tap and press down on the on/off button (red button).
2. Switch off the mains supply and remove the plug.
• You should never leave the compressor air tank unattended while under
pressure.
• Always release the pressure from the tank when not in use or prior to storage,
as described in 'Draining the reservoir' on page 16.
Removing a tool from the air hose
WARNING!
Always set the pressure regulator to zero before attempting to remove or
replace a tool.
1 Stop the power supply by pressing down on the on/off button (red button).
2 Close the air outlet tap and trigger the equipment (spraygun, air tool etc),
to release air from the air hose BEFORE disconnecting the hose from the
machine.
Reset button
This compressor is equipped with a thermal
overload device, which operates as a
safety device to protect the motor.
When the motor overheats for any reason,
the thermal overload automatically cuts
the power thereby preventing damage to
the motor.
Wait around 5 minutes for the motor to cool
and press the reset button. See figure 8.
If you restart the compressor and the
thermal overload activates again, switch
off the compressor, remove the plug from
the mains and have your compressor
checked by a qualified service agent.
Figure 8
16

Warning Symbols

READ THIS INSTRUCTION BOOKLET CAREFULLY BEFORE
POSITIONING, OPERATING OR ADJUSTING THE
COMPRESSOR.
Risk of electric shock. The compressor must be disconnected
from the mains supply before removing any covers. Do not
use in a damp environment.
Risk of accidental start-up. The compressor could start
automatically in the event of a power cut and subsequent
reset. Do not carry the compressor while it is connected to the
power source, or when the tank is filled with compressed air.
This compressor contains surfaces which may reach a high
temperature during operation. Never operate with the motor
housing removed.
Air and condensation water can burst from the compressor
when the drain plug is removed.
Wear a safety goggles and ear protectors when using this
compressor
This compressor produces a high sound level during
operation. Ear protection should be worn.
9