TROUBLE SHOOTING
With considerate use, your CLARKE Air Compressor should provide you with long and
trouble free service. Routine checks should be made on both the electrical supply as
well as the compressed air lines and connections. If any fault appears, the reason for
which is not immediately obvious, please contact your local CLARKE Dealer.
The compressor
Bad connections.
stops and will
not start again.
Overload cutout
switch has tripped.
Motor windings
burnt out.
he compressor
Compressor head
T
does not reach
gasket blown or
the set pressure
valve broken.
and overheats
Worn Piston
easily.
Compressor
Air receiver charged
does not start.
Air leaking from
Faulty non-return
the pressure
valve.
switch valve when
the compressor is
not running.
Air pressure
The diaphragm
from regulator
within the regulator
will not adjust.
body is broken.
CAUTION Do not attempt any repair or adjustment if you are uncertain as to how
it should be done. If you have any queries, contact your local CLARKE Dealer.
Check electrical
connections.
Clean and tighten as
necessary.
witch off and wait 5
S
minutes before switching on.
Contact your local dealer
for a replacement motor.
Contact your CLARKE
dealer.
Replace Piston (contact
your CLARKE dealer)
Open drain cock to expel
air. Compressor should start
again when pressure
reduces to approx. 95 psi.
First drain the receiver
completely. Replace non-
Return Valve
Replace Regulator