保護装置 ABB Relion 620 SeriesのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。ABB Relion 620 Series 4 ページ。

ABB Relion 620 Series クイック・スタート・マニュアル
Q U I C K S TA R T G U I D E R E L I O N ® 6 2 0 S E R I E S
Most common function blocks
The most common function blocks are listed below, please refer to the 620 series Technical Manual for the full list.
The available function blocks varies depending on the selected IED and configuration used.
Function
Protection
Three-phase non-directional overcurrent protection, low stage
Three-phase non-directional overcurrent protection, high stage
Three-phase non-directional overcurrent protection, instantaneous stage
Three-phase directional overcurrent protection, low stage
Three-phase directional overcurrent protection, high stage
Non-directional earth fault protection, low stage
Non-directional earth fault protection, high stage
Non-directional earth fault protection, instantaneous stage
Directional earth fault protection, low stage
Directional earth fault porotection, hig stage
Admittance based earth-fault protection
Wattmetric based earth-fault protection
Transient / intermittent earth-fault protection
Harmonics based earth-fault protection
Negative-sequence overcurrent protection
Phase discontinuity protection
Residual overvoltage protection
Three-phase undervoltage protection
Three-phase overvoltage protection
Positive-sequence undervoltage protection
Negative-sequence overvoltage protection
Frequence protection
Three-phase thermal protection for feeders, cables and distribution transformers
Loss of phase (undercurrent)
Circuit breaker failure protection
Three-phase inrush detector
Master trip
Arc protection
High impedance fault detection
Load shedding and restoration
Multipurpose analog protection
Loss of load supervision
Motor load jam protection
Motor start-up supervision
Phase reversal protection
Thermal overload protection for motors
Motor differential protection
Voltage per hertz protection
Three-phase thermal overload protection for power transformers, two time constants
Stabilized and instantaneous differential protection for 2-winding transformers
Numerical stabilized low impedance resticted earth-fault protection
High impedance based restricted earth-fault protection
IEC 61850
IEC 60617
PHLPTOC
3I>
PHHPTOC
3I>>
PHIPTOC
3I>>>
DPHLPDOC
3I> →
DPHHPDOC
3I>> →
EFLPTOC
Io>
EFHPTOC
Io>>
EFIPTOC
Io>>>
DEFLPDEF
Io> →
DEFHPDEF
Io>> →
EFPADM
Yo> →
WPWDE
Po> →
INTRPTEF
Io> → IEF
HAEFPTOC
Io>HA
NSPTOC
I2>
PDNSPTOC
I2/I1>
ROVPTOV
Uo>
PHPTUV
3U<
PHPTOV
3U>
PSPTUV
U1<
NSPTOV
U2>
FRPFRQ
f>/f<,df/dt
T1PTTR
3lth>F
PHPTUC
3l<
CCBRBRF
3I>/Io>BF
INRPHAR
3l2f>
TRPPTRC
Master Trip
ARCSARC
ARC
PHIZ
PHIZ
LSHDPFRQ
UFLS/R
MAPGAPC
MAP
LOFLPTUC
3l<
JAMPTOC
Ist>
STTPMSU
Is2t n<
PREVPTOC
I2>>
MPTTR
3lth>M
MPDIF
3dl>M
OEPVPH
U/f>
T2PTTR
3lth>T
TR2PTDF
3dl>T
LREFPNDF
dIoHi>
HREFPDIF
dIoHi>
3
ANSI
51P-1
51P-2
50P/51P
67-1
67-2
51N-1
51N-2
50N/51N
67N-1
67N-2
21YN
32N
67NIEFH
51NHA
46
46PD
59G
27
59
47U+
47O-
81
49F
37F
51BF/51NBF
68
94/86
50L/50NL
PHIZ
81LSH
MAP
37M
51LR
49,66,48,51LR
46R
49M
87M
24
49T
87T
87NL
87NH