ELECTRICAL CONNECTIONS

This product is provided with a standard 13 amp, 230 volt (50Hz), BS 1363 plug, for
connection to a standard, domestic electrical supply. Should the plug need
changing at any time, ensure that a plug of identical specification is used.
This appliance is double insulated, and the two wires in the mains lead should
be wired in accordance with the following colour code:
Connect the BLUE coloured wire to the plug terminal marked with a letter "N"
Connect the BROWN coloured wire to the plug terminal marked with a letter "L"
If this appliance is fitted with a plug which is moulded on to the electric cable (i.e.
non-rewireable) please note:
1.
The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.
2.
Never use the plug without the fuse cover fitted.
3.
Should you wish to replace a detachable fuse carrier, ensure that the
correct replacement is used (as indicated by marking or colour code).
4.
Replacement fuse covers can be obtained from your local Clarke dealer
or most electrical stockists.

FUSE RATING

The fuse in the plug must be replaced with one of the same rating (5 amps) and
this replacement must be ASTA approved to BS1362.
If in doubt, consult a qualified electrician. Do not attempt any electrical repairs
yourself.

CABLE EXTENSION

Always use an approved cable extension suitable for the power rating of this tool
(see specifications), the conductor size should also be at least the same size as
that on the machine, or larger. When using a cable reel, always unwind the cable
completely. If using tool outdoors, only use extension cables intended for outdoor
use.
WARNING!
BLUE
-
BROWN
-
NEUTRAL
LIVE