Connect Pump Tube to Air Motor
17. Screw the Cylinder into the Body Assembly.
• Make sure the Gasket has not moved.
18. Tighten the Valve Body into the Cylinder and at the
same time the Cylinder into the Body Assembly.
• Make sure to properly crush the Gaskets.
19. Screw Extension(26) [with Loctite 222] into the Valve
Body.
• Tighten the Extension securely.
Bench Test and Operation
WARNING
Do not exceed the lowest pressure rating
of any component in the system.
Ensure all components are in operable condition.
Replace any suspect parts prior to operation.
Should leakage occur anywhere within the system,
disconnect air to the motor. Personal injury can
occur.
Initial Prime
1. Place the pump in the fluid to be dispensed.
2. Connect a product hose to the pump's fluid outlet.
• Direct the hose into an appropriate collection
container.
3. Screw Adapter (2) [with thread sealant] into the inlet
of the Air Motor Assembly.
4. Screw Valve (3) [with thread sealant] into the Adapter.
5. Screw Adapter (4) into the Valve [with thread sealant].
• Tighten the Adapter securely.
6. Install Air Coupler (5) onto the air supply line.
7. Make sure air pressure at the regulator reads zero.
8. Connect the Air Coupler to the Adapter.
9. Slowly supply air pressure to the pump's motor.
10. Allow the pump to cycle slowly until the fluid is free
of air.
If the pump assembly does not prime, refer to the
Troubleshooting Chart for details.
Revision (10-02)
Starting Pressure
11. Set the air pressure to 30 psi (2.1 Bars).
12. Insert the Adjustment Rod into one of the holes in the
Packing Screw Assembly.
13. Adjust the Packing Screw Assembly until the pump
assembly stops.
14. Loosen the Packing Screw Assembly until the pump
assembly begins to cycle.
Leakage and Stall
WARNING
Should leakage occur anywhere within the
system, disconnect air to the motor. Personal
injury can occur.
With air pressure at zero:
15. Attach a control valve to the outlet hose of the pump.
• Make sure the nozzle on the control valve is open.
16. Slowly supply air pressure to the pump's motor.
17. Allow the pump to cycle slowly until the fluid is once
again free of air.
18. Set the air pressure to the normal operating pressure.
19. Operate the control valve into a container.
20. Shut off the control valve.
• Visually inspect the pump for external leaks.
• The pump should not cycle more than once or twice
in one hour.
If the pump leaks or does not stall, refer to the
Troubleshooting Chart for details.
21. Check the motor for air leakage.
If the motor leaks, refer to the Air Motor Service
Guide for details.