A 1" BSP hose adapter will be required for connection
to the inlet and outlet port. These are available from
your CLARKE dealer.
A foot valve and filter should be fitted to the lower
end of the suction hose as illustrated, so as to help
retain water in the suction system and to prevent the
possibility of large foreign bodies arriving at the
pump/cartridge filter.
A gate valve may be installed in-line on the outlet
side of the pump which can be set as required to
regulate the flow of water. Do not place any such
restriction on the suction side of the pump unless it is
an isolator valve in a gravity fed system.
THE INLET FILTER
An inlet filter is supplied with the
CBT1300SS pump. The filter bowl is
transparent, allowing a visual check
as to the condition of the filter
cartridge. The filter cartridge is a
washable net type with a rated
filtration of 60 microns, suitable for the
efficient removal of suspended
particles such as sand.
The filter is NOT designed to filter mud,
sludge etc and should hang vertically
when installed.
PREPARATION FOR USE
THE PRESSURE VESSEL
This unit operates as a booster pump
by utilising an air chamber with a
pressure regulator switch to provide a
constant pressure at the outlet. The
pump will automatically cut in when
the water pressure reduces to 1.4 Bar
and cut out when the pressure
reaches 3.5 Bar.