水ポンプ Clarke PSV1AのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Clarke PSV1A 11 ページ。 Dirty water pump
USING THE PUMP
CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT IS
1
Place the pump on a flat surface in the area that you want to drain.
•
If there is sediment in the operating area, the pump should be placed on house
bricks, or similar.
•
Ensure the pump is positioned with adequate space so that the movement of the
float switch is not restricted - recommended minimum area of 40 x 40cm
•
ALWAYS raise and lower the pump using a rope attached to the lifting handle.
•
Take all necessary precautions as described on page 4 before plugging in, and
switching ON.
NEVER CARRY THE PUMP USING THE MAINS POWER CABLE. DAMAGE TO
ELECTRICAL CABLES CAN BE DANGEROUS. ALWAYS USE THE HANDLE WHEN
2
Connect the mains plug to a high sensitivity residual current device (RCD) which has
a tripping current of less then 30mA.
3
Switch the mains power supply on,
•
The pump incorporates a float switch, which automatically switches the pump
ON when the water is above a pre-determined level.
4
The pump will begin to drain water.
• As the water level falls, so will the float switch, until it stops the pump.
5
When the pumping is finished, disconnect the pump from the mains power supply
•
The pump is fitted with a thermal cut out to protect the motor from overheating.
If the thermal cut out activates, the motor will automatically switch back on
when it has cooled down sufficiently.
DO NOT ALLOW THE PUMP TO RUN DRY.
CAUTION!
DAMAGED IN ANY WAY
WARNING!
MOVING THE PUMP.
CAUTION!