- ページ 2
配管製品 Acorn Terrazzo-Ware SBADA-6030のPDF インストレーション、オペレーション&メンテナンスマニュアルをオンラインで閲覧またはダウンロードできます。Acorn Terrazzo-Ware SBADA-6030 3 ページ。 Shower bases
HANDLING
1
Carefully remove Shower Base from carton at
installation point. Avoid placing Shower Base
on its edge. (This precaution will prevent
damage to corners of Shower Base.)
METHOD FOR CHECKING FACE OF Shower
Base FOR TRANSPORTATION DAMAGE:
A. Wipe face of Shower Base with a wet
cloth (Water).
B. When the water evaporates, any slight
crack in the Shower Base will be
noticeable.
LEVELING
2 2
Level Shower Base carefully. For proper
installation, establish a 1/4" clearance
between Shower Base and the walls. A 1/2"
layer of mortar or sand must be placed in
area where the Shower Base is to be
installed. This procedure is recommended in
order to support Shower Base should the
sub floor be uneven. Grout should be
exposed along edges.
NOTE: Mortar or sand must cover the entire
area between Shower Base and building
floor.
*NOTE: Inspect and test for proper
drainage.
ADA Shower Base to be recessed. Check
local authority for code and installation
requirements.
WARNING!
2 3
DO NOT DROP SHOWER BASE OVER
EXPOSED PIPE.
It is advisable to remove drain pipe and set
Shower Base in place. Insert pipe through
drain in Shower Base back into "P" trap.
Tighten with an internal pipe wrench.
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
TERRAZZO-WARE SHOWER BASES
REMOVE SHOWER BASE CAREFULLY
FROM CARTON
REMOVE PACKAGING
WITH CARE
1/4"
RECOMMENDED
1/4" SPACE
DOTTED AREA IS
FOR MOP SINK
DO NOT DROP
ON PIPE
REMOVE PIPE
FROM TRAP
ACORN ENGINEERING FIELD SERVICE
2
TM
AVOID STANDING
SHOWER BASE ON END
1/2" SAND OR
MORTAR BED
SUB FLOOR
GROUT EXPOSED
SIDES
REINSERT PIPE AND TIGHTEN
WITH AN INTERNAL WRENCH