- ページ 7
産業機器 Alemite 8592のPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Alemite 8592 8 ページ。 Portable used fluid drain
8592
Accessories
343354 Bung Adapter
F401 Rotary Hand Pump
Where an evacuation system is not available, the tank
can easily be emptied with an F401 Rotary Hand Pump.
The Rotary Hand Pump is installed on the tank in place
of the Camlock fitting/suction tube assembly using the
special bung adapter 343354. The Rotary Hand Pump
and the Bung Adapter can be purchased separately.
Accessories Installation
343354
Step 1: Install 343354 Bung Adapter (with indicator groove down)
on Drain in place of original Camlock/Suction Tube Assembly.
A
e l
m
i
e t
L ,
C L
Portable Used Fluid Drain
F401 Bung
Adapter
Step 2: Install Bung Adapter from F401 Hand Pump package onto
343354 Bung Adapter.
Step 3: Install F401 Hand Pump Assembly in its Bung Adapter and
tighten Thumbscrew to position pump. Do not over tighten screw.
7
F401 Rotary
Hand Pump
0
- 2
0 2
0 2