- ページ 7
計測機器 Alemite 3575-BのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Alemite 3575-B 8 ページ。 Oil control handle with mechanical meter
SER 3575A
Troubleshooting
Trouble
Meter not accurate
No fluid passing through the meter
The meter is not registering fluid
output
Constant oil leak from the nozzle
Intermittent drip from the nozzle
particles, replace if necessary.
Oil leak from the lever assembly area
Oil leak from between the body handle
and housing gear box
Low flow rate
Oil leaking from the swivel inlet
Specifications
Accuracy
+ - 1% (of Reading)
Flow Range
1-30 l/min (0.26 – 8 US gal/min)
Operating Pressure
0-13.79 Bar / 0-3447 kPa / 0-200 PSI
Maximum Pressure
103.50 BAR / 10350 kPa / 1500 PSI
1Bar/ 100 kPa / 14.4 PSI @ 12 l/min (3.2 US)
Pressure Loss
gal/min) with calibration fluid (6 Centipoise
Viscosity) without extension
Weight
1.16 kg ( 2.55 lbs)
25.8 cm (10 inch) Long x 9.5 cm ( 3.7 inch)
Dimensions:
High, x 11 cm (4.33 inch) Wide (Dimensions
without extension)
Alemite, LLC
Cause
Flow rate not correct
a) Blocked strainer
b) Dirt particles jamming the rotors
c) Damaged plunger seal
a) Damaged register assembly (4)
b) Damaged gear or gears (5,13,15,16, 17)
Damaged plunger seal (29)
Dirt in the nozzle (50)
Damaged o-rings (23, 25)
Damaged o-rings (21)
Blocked strainer (35)
Damaged o-ring or swivel
Swivel Inlet
Outlet
Operating Temperature:
Wetted Parts:
Fluid Compatibility:
Solution
Adjust flow rate to 1-30 l/min (0.26 – 8 US gal/min)
a) Clean or replace strainer
b) Dismantle meter assembly and clean (refer to meter
disassembly)
c) Replace damaged plunger seal
a) Replace register assembly
b) Replace complete gear set, also replace (12) shaft
and (9) O-ring.
Replace plunger seal (check for damage)
Remove the nozzle and blow out any dirt
Replace damaged o-rings
Replace damaged o-rings
Replace strainer
Replace swivel
1/2" NPT
3/8"
-10 to 55 °C (14 to 131 °F)
Aluminium, Acetal, Steel, Nitrile Rubber
Engine Oil, Diesel Oil, Automatic
Transmission Fluid, Anti-freeze / Anti-Boil
Mixture. (Maximum Viscosity SAE140)
7
Mechanical Meter Oil Control Handle
Initial Release 10-15