- ページ 8

ヒーター Clarke Devil 6015のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Clarke Devil 6015 20 ページ。 Electric fan heaters
Clarke Devil 6015 にも: 取扱説明書 (20 ページ)

Clarke Devil 6015 取扱説明書

OPERATION

The Devil range of fan assisted electric heaters are suitable for household
(Devil 6003 only) or workshop/factory use. They incorporate a thermostat
which detects the temperature of the room air and controls the heater to
maintain a pre-selected temperature between 0 & 40°C. A manually reset
thermal cutout is provided for safety in the event of overheating on the 6005,
6009 & 6015 models. The fan motor runs independently of the thermostat and
continues running after the heating element has been switched off.
With the heater suitably sited (ensure you comply with all safety precautions),
switch the heater ON to the chosen setting as follows:
3 KW HEATERS
The 3kw heater has 3 running speeds for the fan incorporating 2 settings for
both of the heating elements once the fan is set running. The other control is
a progressive thermostat which is rotated through 270 deg. A cutout is used
to maintain a constant pre-set temperature.
3-position fan speed control
thermostatic temperature control
When using the heater to warm a cold room, first turn the thermostat to MAX
and run the heater on full power until the room temperature reaches the
required value, then turn the thermostat anti-clockwise until it switches off.
The thermostat will then switch the heater on and off automatically to control
the room temperature according to the pre-set value, maintaining a con-
stant room temperature. The 3kw unit is fitted with a self-resetting thermal
cutout.
8