- ページ 7

ツール Clarke CAT139のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Clarke CAT139 13 ページ。 Air hammers

Clarke CAT139 取扱説明書
2. Connect a suitable hose as shown.
3. Connect the other end of the hose
to the compressed air supply.
4. Turn on the air supply and check
for air leaks. Rectify any found
before proceeding.
• PTFE tape may be helpful for
sealing threaded connections.
5. Your air tool is now ready for use.

FITTING THE CHISEL

1. First remove the retaining spring
from the nose by unscrewing it.
• Use the inboard lug to gain
purchase.
2. Insert the chisel into the air
hammer as shown.
3. Replace the retaining spring as
shown.
• Use the lugs to tighten.

USING THE AIR HAMMER

1. Hold the tool firmly, then bring the
tool towards the work at an angle
of approximately 60-70 degrees.
2. Pull the trigger with the chisel in
light contact with the work.
3. Move slowly across the work
surface. To remove scale, rust or
other contaminants, only a light
force should be required.
4. Release the trigger to stop operation, whilst maintaining contact with the
work.
NOTE: that the tool may impact briefly after the trigger is released.
NOTE: The retaining spring has a life expectancy, depending upon the
intensity of usage. It is recommended that you procure a spare
spring for use in the event of failure occurring during the course of
a particular job.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
7