Disposal of all waste solvent and sludge must be tracked and documentation of proper
disposal kept on file.
B.

Filter Disposal.

As the filters of the Parts Washer plug over time, they will need to be changed out and
disposed of properly
The owner of the Parts Washer is responsible for contacting all local, county, state,
provincial and federal agencies regarding handling and disposal of used filters and
oilsorbs. Obtain these rules in writing and keep them on hand for reference.
To document compliance, owners must follow these guidelines and track all disposal
times and charges with receipts.
IX.

TROUBLE-SHOOTING

Light doesn't work:

A.
1. Check power cord, is it plugged into electrical box plug labeled "light bar"?
2. Replace light bulb, 150-watt halogen.
3. Confirm parts washer is plugged into wall outlet.

Fusible Link doesn't line-up with tab on lid:

B.
1. Adjust bolt on fusible link.
2. Switch fusible link to other side of mount on light bar.
3. Loosen and realign light bar and retighten in correct position.
4. Never bend Fusible Link, this will weaken it!
Air Gun has low pressure or doesn't work:
C.
1. Check air source.
2. Check adjustment of regulator.
3. Check air hose for kinks or damage.
4. Confirm air pump is plugged in to the electrical box plug.

Soak Tank Pump doesn't work:

D.
1. Check for defective power cord; plug in pump with extension cord.
2. Inspect pump base screen and impeller for damage or obstruction.
E.

Wand/Brush leaking or drips:

1. Tighten fittings.
2. Remove fittings and remove Teflon tape, then re-tape and re-assemble.
3. Tighten hose clamps.
4. Check for damage and wear, replace as necessary.