Pump running but not pumping fluid:
1. Remove fluid from tank, remove intake and discharge hose from pump. Use
compressed air to clear hoses.
2. Remove front cap on pump and check for debris or wear. Replace if necessary.
J.
Main Pump leaking:
1. Inspect for damage.
2. Remove front head assembly and inspect for proper assembly, blow clean with
air gun and reassemble.
K.
Sludge Pump leaking:
1. Inspect for cracks, damage or wear
L.
Plumbing leaking:
1. Tighten hose clamps.
2. Check all hose connections and hoses for wear or damage and replace if
necessary.
3. Remove plumbing fitting and re-tape with Teflon tape. Re-install and tighten.
M.
No Power Main Pump, Light, Soak Tank Pump do not work:
1. Confirm power to wall outlet.
2. Check fuse (10Amp) on lower box.