2. Technical characteristics
The technical specifications in the chart below are given for the models according to the type
of refrigerant used.
Description
Max. absorbed power
Net weight
Overall dimensions (HxLxP)
Fully charged weight
Vacuum flow rate
Max. vacuum
Filter absorption capacity (rate)
System recovery rate
Refrigerant cylinder capacity
Supply voltage
Supply frequency
Max. absorbed current
Coupling diameter on vehicle (Low Pressure LP)
Coupling diameter on vehicle (High pressure HP)
Max. operating temperature
Min. operating temperature
Max. pressure pneumatic circuit
For supply voltage, always use the value indicated on the machine plate.
The acoustic pressure value for the machine is below 70dBA and therefore no special
precautions need to be taken by the operator even in the case of continuous use
(standard ISO 3746). However, it is the responsibility of the employer to evaluate
noise level exposure of workers in compliance with the directives concerning work
hygiene and safety.
Logika - use and maintenance guide
Unit
R12
Measure
Values
W
800
Kg
81
Mm
1040x540x600
kg
100
lt/min
66
mbar
0.01
gr H 2 O
80
gr/min
400
kg
10
V
220/240
Hz
50
A
5,0
mm
11
mm
11
°C
50
°C
5
bar
18
R134a
Values
800
81
1040x540x600
100
66
0.01
80
400
10
220/240
50
5,0
13
16
50
5
18