照明器具 Clas Ohlson 18-1176のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Clas Ohlson 18-1176 5 ページ。 Led rectangular downlights (led-spotlights)

Clas Ohlson 18-1176 クイック・スタート・マニュアル
LED Rectangular Down-
light/s (LED-spotlight/s)
Art.no. 18-1176
Model XH-B01033-UK
18-2712
XH-B01030-UK
36-3759
XH-B01033
36-3861
XH-B01030
36-4941
XH-B01033
36-4942
XH-B01030
Please read the entire instruction manual before using
the product and save it for future reference. We reserve
the right for any errors in text or images and any necessary
changes made to technical data. If you have any questions re-
garding technical problems please contact Customer Services.
Safety
• The product is intended for indoor use only.
• Installation and maintenance may only be carried out be
a qualified tradesman according to local safety regulations.
• The lighting fixture may not be used if any part is damaged.
It should either be discarded or repaired by a qualified
technician.
• Only use the enclosed transformer as a power source.
None of the product's parts are to be disassembled
or modified.
• Do not cover the transformer or lights with anything that
will hinder proper ventilation such as e.g. foil, paper,
plastic, etc.
• Make sure that the leads are not set against sharp corners
or edges.
• The rating label containing the model number may not be
removed or made to be unreadable.
• The transformer is only designed for supplying power to
an LED lighting fixture of max 15 W.
Package contents
18-1176/36-3759/36-4941 3 × LED downlights with stainless
steel housing and transformer.
18-2712/36-3861/36-4942 1 × LED downlight with
stainless steel housing.
GREAT BRITAIN • customer service tel: 08545 300 9799 e-mail: [email protected] internet: www.clasohlson.com/uk
Installation/mounting
Can be surface mounted with the included housing or flush
mounted in an Ø 60 mm opening.
1. Press the light fixture (1) gently from its housing (3).
2. Screw the housing (3) into an appropriate spot with
a screw (2). Plan out the positioning of the power lead
before you begin installation. It is also possible to flush
mount the lighting fixture/s into an Ø 60 mm opening.
3. Press the lighting fixture (1) securely into its housing (3)
(or into a 60 mm opening).
4. Connect the lead end from the light fixture to one of
the junction box's DC connections.
5. Connect the plug to a wall socket.
6. Power to the light fixture is operated by the in-line switch.
2
3
1
Transformer
Junction box
with
DC-connections
Care and maintenance
• Always unplug the mains lead before cleaning.
• Wipe with a soft, lightly moistened cloth. Never use strong
solvents or cleaning agents.
Disposal
Follow local ordinances when disposing of this
product. If you are unsure of how to dispose of this
product, please contact your municipality.
Specifications
Transformer
Input
Output
Power
Ta
Tc
Lead
Protection class IP20
Spotlight
LEDs
Sizes
Housing
In-line switch
230 V AC, 50 Hz
12 V DC, 1.25 A (5x)
Max. 15 W
50 ºC
75 ºC
H03VVH2-F, 2 × 0.5 mm²
18 x warm white LEDS, 3 W total, 12 V DC
Light fixture: Flush mounted measurement:
Ø 60 mm, exterior diameter (light holder):
Ø 69 mm, mounting depth: 16 mm.
120 × 85 mm