- ページ 5

ウォーター・ディスペンサー ACORN AQUA A511105FのPDF 設置、操作、メンテナンスの説明書をオンラインで閲覧またはダウンロードできます。ACORN AQUA A511105F 8 ページ。 Aquacold series compact free standing water coolers

d. Check the water inlet strainer. Sediment from the main supply can get trapped in the
screen along with installation materials such as pipe dope and flux. The screen should
be cleaned and checked on a regular basis and replace if needed.
e. The cartridge valve located in the water control assembly or bubbler can also become
clogged with foreign material. The cartridge valve can only be replaced and not repaired.
f.
The water cooler may also develop a freezing condition in which the water will become
frozen inside the evaporator coil. This indicates a refrigeration problem or thermostat
failure in which case the water cooler needs to be checked by a qualified technician.
CLEANING & MAINTENANCE GUIDE:
1. Motors have lifetime lubrication and do not require scheduled maintenance.
2. Excess dirt or poor ventilation will cause the compressor overload protector to turn the
compressor off and it will cycle on and off with no cold water coming out of bubbler. Periodically
clean with vacuum cleaner, air hose or brush the condenser fins and cabinet ventilation louvers.
In environments where dirt and dust is more prevalent, clean more frequently .
3. Periodically remove access panels and clean out in-line strainer .
4. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the
Acorn Aqua warranty.
5. Exterior panels can be cleaned using mild household detergents or warm, soapy water . Extra
care must be used cleaning chrome plated items and mirror finished stainless steel. They can
scratch easily and should only be cleaned using a clean, soft cloth and mild soap with water or
a mild glass cleaner.
L1001054
Page 5 of 8
Revised: 07/27/10