- ページ 2

会議システム DIS CU 6105のPDF データシートをオンラインで閲覧またはダウンロードできます。DIS CU 6105 3 ページ。 Central unit

Specifications

Electrical
Power consumption max. 150W/48V
Supply voltage for units 125W/48V
Audio quality
Frequency response 65 Hz-16 kHz
THD < 0.1 %
Signal-to-noise ratio > 85 dBA
Audio inputs
Analog audio in 1
Analog audio in 2 (Audio in
or Emergency input - EEM)
Audio outputs
Analog audio out (A, B, C
and D)
Maximum load > 1 k ohm
Interconnections
DCS-LAN Two RJ45 female sockets
EEM One contact closure input
System Performance (feature license dependant)
Max. number of conference
units (excl. CS)
Max. number of IS
(Interpreter Units)
Max. number of IS units in
one booth
Max. number of A0 (Audio
Output Units)
Max. number of CS (Channel
Selector Units)
Max. number of languages 16
Max. number of open
"floor"microphones
Mechanical
Mounting
Color Black
Dimensions without feet (H
x W x D)
Weight 2800 g
24 bit audio, 32 kHz sampling
frequency
3-pin female XLR sockets
(electronically balanced)
3-pin female XLR sockets
(electronically balanced)
Four 3-pin male XLR sockets
(electronically balanced)
500
150
32
20
unlimited
8
Tabletop or mounted in a 19''
one unit rack
44.4 x 426 x 186 mm
Storage temperature
Optimal operating
temperature
PS CU External Power Supply
Main voltage 100-240 V, 50-60 Hz
Max. consumption 175 W
Total supply power 150 W
Standby consumption <0.5 W
Supply voltage for CU 6105 48V/3A
Certifications
The DCS 6000 system conforms to standard IEC 60914.
PS CU approvals CE, KC, CCC, cULus, TÜV
How To Order
CU 6105 Central Unit 15 09 58100
Included accessories
• PS CU External Power Supply
• Power cable (EU connector), 1 piece
• 19" brackets, 1 set
• Tool for fixing GM to XLR
-20° to 60° C, 10-80%
humidity
5° to 40° C, 35-80% humidity